Loading...
Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFSM0003N Timed Out waiting on boot permission from Management Module:
System Halted.
Warning
FQXSFSM0004M An XCC communication failure has occurred.
Warning
FQXSFSR0001M [arg1] GPT corruption detected, DiskGUID: [arg2]
Warning
FQXSFSR0003G The number of boot attempts has been exceeded. No bootable
device found.
Warning
FQXSFTR0001L
An invalid date and time have been detected. Warning
FQXSFDD0004M DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required
Controller.
Error
FQXSFDD0008K Self-Encrypting Drive (SED) Error: failed to get key.
Error
FQXSFDD0009K Self-Encrypting Drive (SED) Error: failed to access drive [arg1]. Error
FQXSFDD0010K Self-Encrypting Drive (SED) Error: failed to unlock drive [arg1].
Error
FQXSFDD0011K Self-Encrypting Drive (SED) Error: failed to set password to drive
[arg1].
Error
FQXSFDD0012K SATA Hard Drive Error: [arg1].
Error
FQXSFIO0005M An intra-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
Error
FQXSFIO0006M An inter-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
Error
FQXSFIO0007M An error has been detected by the IIO on Bus [arg1]. The value of
Global Fatal Error Status register is [arg2]. The value of Global Non-
Fatal Error Status register is [arg3]. Please check error logs for
additional downstream device error data.
Error
FQXSFIO0010M An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical [arg6] number is [arg7].
Error
FQXSFIO0011M A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The Physical slot number is [arg6].
Error
FQXSFIO0012M A PCIe system error has occurred on Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The Physical slot number is [arg6].
Error
FQXSFIO0014J A bad option ROM checksum was detected for the device found at
Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device
is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
Error
FQXSFIO0017M IFM: Error communicating with the XCC - IFM may not be deployed
correctly.
Error
FQXSFIO0019J PCIe Resource Conflict [arg1].
Error
FQXSFIO0024M An error has been detected by the IEH on processor [arg1]. The type
of IEH is [arg2]. The index of the IEH is [arg3]. The value of
IehErrorStatus register is [arg4]. Please check error logs for additional
downstream device error data.
Error
142 ThinkSystem SE350 V2 Messages and Codes Reference