Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPSS4011I Fan speed boost setting is changed from [arg1] to [arg2]. Informational
FQXSPTR4000I Management Controller [arg1] clock has been set from NTP server
[arg2].
Informational
FQXSPTR4001I Date and Time set by user [arg1]: Date=[arg2], Time-[arg3], DST Auto-
adjust=[arg4], Timezone=[arg5].
Informational
FQXSPTR4002I Synchronize time setting by user [arg1]: Mode=Sync with NTP Server,
NTPServerHost1=[arg2]:[arg3],NTPServerHost2=[arg4]:[arg5],
NTPServerHost3=[arg6]:[arg7],NTPServerHost4=[arg8]:[arg9],
NTPUpdateFrequency=[arg10].
Informational
FQXSPTR4003I Synchronize time setting by user [arg1]: Mode=Sync with server
clock.
Informational
FQXSPUN0017I Sensor [SensorElementName] has transitioned to normal state. Informational
FQXSPUN0026I Device [LogicalDeviceElementName] has been added. Informational
FQXSPUN2009I Sensor [SensorElementName] has deasserted. Informational
FQXSPUN2012I Sensor [SensorElementName] has deasserted. Informational
FQXSPUN2018I Sensor [SensorElementName] has deasserted the transition from
normal to non-critical state.
Informational
FQXSPUN2019I Sensor [SensorElementName] has transitioned to a less severe state
from critical.
Informational
FQXSPUN2023I Sensor [SensorElementName] has deasserted the transition to non-
recoverable.
Informational
FQXSPUN2050I The RAID controller in PCI slot [arg1] is no longer in critical status. Informational
FQXSPUP0002I A firmware or software change occurred on system
[ComputerSystemElementName].
Informational
FQXSPUP4001I Flash of [arg1] from [arg2] succeeded for user [arg3] . Informational
FQXSPUP4002I Flash of [arg1] from [arg2] failed for user [arg3]. Informational
FQXSPUP4006I Auto promote primary XCC to backup is [arg1] by user [arg2] from
[arg3] at IP address [arg4].
Informational
FQXSPWD0000I Watchdog Timer expired for [WatchdogElementName]. Informational
FQXSPWD0001I Reboot of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0002I Powering off system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0003I Power cycle of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0004I Watchdog Timer interrupt occurred for [WatchdogElementName]. Informational
FQXSPBR4001I Running the backup Management Controller [arg1] main application. Warning
FQXSPCA0007J Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
Warning
FQXSPDM4002I Device [arg1] VPD is not valid. Warning
Chapter 2. XClarity Controller events 21

Related product manuals