Loading...
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0286
User Action:
Please ensure bootable media be installed correctly.
FQXSPCA0002M: Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Fan Failure
SNMP Trap ID: 11
CIM Prefix: PLAT CIM ID: 0480
User Action:
Complete the following steps:
1. Ensure fans are installed correctly.
2. If fan is installed with issue , please reinstall fan.
3. If the problem still exist, then please contact Lenovo support.
FQXSPCA0007J: Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted.
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Temperature
SNMP Trap ID: 12
CIM Prefix: PLAT CIM ID: 0490
User Action:
if there are dust filter in system, make sure that dust filter is clean.
FQXSPCA0009M: Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0494