Loading...
FQXSPSD2013I: Array critical deasserted on drive [arg1] in the enclosure/chassis (MTM-S/N:
[arg2]).
This message is for the use case when an implementation has detected that an Critiacal Array has
deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0175
User Action:
Information only; no action is required
FQXSPSD2014I: Array restored on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that a Failed Array has been
Restored.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0177
User Action:
Information only; no action is required
FQXSPSD2015I: Array rebuild completed on drive [arg1] in the enclosure/chassis (MTM-S/N:
[arg2]).
This message is for the use case when an implementation has detected that an Array Rebuild has
Completed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0179
User Action:
Information only; no action is required
FQXSPSE0000F: The Chassis [PhysicalPackageElementName] was opened.
This message is for the use case when the Chassis has been opened.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0004
User Action:
Chapter 2. XClarity Controller events 113