Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFMA0005N Memory is present within the system but could not be configured. 
Please verify that the memory configuration is valid. [arg1]
Error
FQXSFMA0008M DIMM [arg1] has failed the POST memory test. [arg2]
Error
FQXSFMA0027K Invalid memory configuration (Unsupported DIMM Population) 
detected. Please verify memory configuration is valid.
Error
FQXSFPU0016N A processor within the system has failed the BIST.
Error
FQXSFPU0017G A processor microcode update failed. Error
FQXSFPU0018N CATERR(IERR) has asserted on processor [arg1]. Error
FQXSFPU0019N An uncorrectable error has been detected on processor [arg1].
Error
FQXSFPU0030N A firmware fault has been detected in the UEFI image. Error
FQXSFPU0031N The number of POST attempts has reached the value configured in F1 
setup.The system has booted with default UEFI settings. User 
specified settings have been preserved and will be used on 
subsequent boots unless modified before rebooting.
Error
FQXSFPU0034L The TPM could not be initialized properly. Error
FQXSFPU4056M TPM/TCM card is changed, need install back the original TCM/TPM 
card which shipped with the system.
Error
FQXSFSM0008M
Boot permission timeout detected. Error
List of UEFI events
This section lists all messages that can be sent from UEFI.
•  FQXSFDD0001G: DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings 
From F1. 
Severity: Warning
User Action:
Complete the following steps:  
1.  Go to F1 Setup > System Settings > Settings > Driver Health Status List and find a driver/controller 
reporting Configuration Required status.
2.  Search for the driver menu from System Settings and change settings appropriately.
3.  Save settings and restart the system.
4.  If the problem persists, collect Service Data logs and contact Lenovo Support.
•  FQXSFDD0002M: DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller. 
Severity: Warning
User Action:
Complete the following steps:  
1.  Reboot the system.
2.  Reflash the adapter firmware.
148
ThinkSystem SR250 V3 Messages and Codes Reference