Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPUP4004I XCC firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the XCC firmware to the same level on all
nodes/servers.
Error
FQXSPUP4005I FPGA firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the FPGA firmware to the same level on all
nodes/servers.
Error
List of XClarity Controller events
This section lists all messages that can be sent from the XClarity Controller.
• FQXSPBR4000I: Management Controller [arg1]: Configuration restored from a file by user [arg2].
This message is for the use case where a user restores a Management Controller configuration from a file.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0027
User Action:
Information only; no action is required.
• FQXSPBR4001I: Running the backup Management Controller [arg1] main application.
This message is for the use case where a Management Controller has resorted to running the backup
main application.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0030
User Action:
Complete the following steps until the problem is solved:
1. Update the BMC firmware.
2. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPBR4002I: Management Controller [arg1] Reset was caused by restoring default values.
This message is for the use case where a Management Controller has been reset due to a user restoring
the configuration to default values.
Severity: Info
Serviceable: No
26
ThinkSystem SR250 V3 Messages and Codes Reference