Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFPU4033F TPM Firmware recovery is in progress. Please DO NOT power off or
reset system.
Warning
FQXSFPU4035M TPM Firmware recovery failed. TPM chip may be damaged. Warning
FQXSFPU4040M TPM selftest has failed. Warning
FQXSFPU4043G TPM Firmware update aborted. System is rebooting...
Warning
FQXSFPU4050G
Failed to update TPM Firmware. Warning
FQXSFPU4051G Undefined TPM_POLICY found Warning
FQXSFPU4052G TPM_POLICY is not locked Warning
FQXSFPU4053G System TPM_POLICY does not match the planar. Warning
FQXSFPU4054G TPM card logical binding has failed. Warning
FQXSFPU4057I Secure boot variable is being accessed with an unauthorized
password, reset the system immediately to recover.
Warning
FQXSFPU4058I Secure Boot Setting is changed from enabled to disabled Warning
FQXSFPW0001L CMOS has been cleared.
Warning
FQXSFSM0002N Boot Permission denied by Management Module: System Halted.
Warning
FQXSFSM0003N Timed Out waiting on boot permission from Management Module:
System Halted.
Warning
FQXSFSM0004M An XCC communication failure has occurred.
Warning
FQXSFSR0001M [arg1] GPT corruption detected, DiskGUID: [arg2]
Warning
FQXSFSR0003G The number of boot attempts has been exceeded. No bootable
device found.
Warning
FQXSFTR0001L
An invalid date and time have been detected. Warning
FQXSFDD0004M DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required
Controller.
Error
FQXSFDD0012K SATA Hard Drive Error: [arg1].
Error
FQXSFIO0005M An intra-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
Error
FQXSFIO0006M An inter-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
Error
FQXSFIO0007M An error has been detected by the IIO on Bus [arg1]. The value of
Global Fatal Error Status register is [arg2]. The value of Global Non-
Fatal Error Status register is [arg3]. Please check error logs for
additional downstream device error data.
Error
FQXSFIO0010M An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical [arg6] number is [arg7].
Error
FQXSFIO0011M A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The Physical slot number is [arg6].
Error
Chapter 3. UEFI events 139