Do you have a question about the Lenovo ThinkSystem SR650 and is the answer not in the manual?
Tcase | 81 °C |
---|---|
Stepping | M0 |
Scalability | 4S |
Processor code | SR3GF |
Processor cache | 16.5 MB |
Processor cores | 12 |
Processor model | 5118 |
System bus rate | - GT/s |
Processor socket | LGA 3647 (Socket P) |
Processor threads | 24 |
Processor codename | Skylake |
Execute Disable Bit | Yes |
Processor frequency | 2.3 GHz |
Processor cache type | L3 |
Processor lithography | 14 nm |
Processor manufacturer | Intel |
Processor package size | 76.0 x 56.5 mm |
Processor boost frequency | 3.2 GHz |
Processor operating modes | 64-bit |
Supported instruction sets | AVX, AVX 2.0, AVX-512, SSE4.2 |
Thermal Design Power (TDP) | 105 W |
Number of processors installed | 1 |
Maximum number of PCI Express lanes | 48 |
Memory types supported by processor | DDR4-SDRAM |
Memory channels supported by processor | Hexa |
Memory clock speeds supported by processor | 2666 MHz |
Maximum internal memory supported by processor | 768 GB |
Memory slots | 24x DIMM |
Internal memory | 32 GB |
Maximum internal memory | 3072 GB |
Memory layout (slots x size) | 1 x 32 GB |
Power supply | 750 W |
Power supply input frequency | 50 - 60 Hz |
HDD size | - \ |
RAID levels | 0, 1, 5, 6, 10, 50, 60, JBOD |
Optical drive type | No |
Supported HDD sizes | 2.5 \ |
Total storage capacity | 0 GB |
Maximum storage capacity | 61.4 TB |
Number of HDDs installed | - |
Supported storage drive interfaces | SAS, Serial ATA III |
Cabling technology | 10/100/1000Base-T(X) |
USB 2.0 ports quantity | USB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them. |
PCI Express slots version | 3.0 |
PCI Express x8 (Gen 3.x) slots | 2 |
Chassis type | Rack (2U) |
Performance management | XClarity Enterprise |
Trusted Platform Module (TPM) version | 1.2 |
Operating altitude | 0 - 3048 m |
Storage temperature (T-T) | -10 - 60 °C |
Operating temperature (T-T) | 5 - 45 °C |
Operating relative humidity (H-H) | 8 - 90 % |
Sustainability certificates | ENERGY STAR |
Processor ARK ID | 120473 |
Intel TSX-NI version | 1.00 |
Depth | 763.7 mm |
---|---|
Width | 482 mm |
Height | 86.5 mm |
Describes the status of the power input LED, indicating connection to the AC power source.
Explains the power output LED states for server operation, standby, and faults.
Details the power supply error LED, indicating failure and the need for replacement.
Provides initial instructions on how to remove a hot-swap power supply from the server.
Cautions regarding high voltage within components marked with hazard labels.
Ensures all electrical current is removed by disconnecting all power cords.
DANGERS and key steps to avoid electrical shock hazards when handling cables.
Provides steps for connecting and disconnecting power supplies.
Specifies that hot-swap functionality requires two power supplies for redundancy.
Warning that DC power controls may not disconnect all current; all connections must be removed.
DANGERS and precautions for avoiding electrical shock hazards with DC power.
Instructions to adjust the CMA to access the power supply bay.
Step to disconnect the power cord from the hot-swap power supply.
Procedure for sliding the power supply out of the chassis.
Guidance on inserting a new power supply or filler for cooling.
Requirement for an additional power supply for redundancy and hot-swap support.
Ensures that two installed power supplies must have the same wattage.
DANGERS and precautions for avoiding electrical shock hazards.
Warning against hot-plugging DC supplies to prevent equipment damage and data loss.
Caution that DC power controls may not disconnect all current; all connections must be removed.
DANGERS and precautions for avoiding electrical shock hazards with DC power.
Instructions to adjust the CMA for access to the power supply bay.
Instructions to remove a power-supply filler if one is installed.
Steps to slide the new hot-swap power supply into the bay until it secures.
Ensures power input and output LEDs are lit after installation and server power-on.