Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPEM4026I Drive error was detected by RAID controller. Please contact technical
support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4027I
Drive error was detected by RAID controller. Please check the event
logs and if events are targeted to the same disk then replace the drive.
If necessary, contact technical support for additional assistance.
([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4028I The port [arg1] of PCIe device [arg2] at [arg3] has link [arg4]. Informational
FQXSPEM4029I All PCIe slots on [arg1] may not be functional based upon your current
CPU population.
Informational
FQXSPEM4030I
A scheduled operation on the RAID controller has encountered an
issue. Refer to RAID Logs under Server Management, Local Storage,
for details.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4031I SSD wear threshold setting is changed from [arg1] to [arg2] by user
[arg3] from [arg4] at IP address [arg5].
Informational
FQXSPEM4032I Acoustic Mode [arg1] has been engaged. Fan speed limits are in
place.
Informational
FQXSPEM4033I Acoustic Mode [arg1] has been disengaged to allow adequate
cooling.
Informational
FQXSPEM4036I Dust filter measurement schedule is configured on server [arg1] by
user [arg2] from [arg3] at IP address [arg4].
Informational
FQXSPEM4037I Attempting to perform scheduled dust filter measurement on server
[arg1].
Informational
FQXSPEM4038I Dust filter measurement schedule is disabled on server [arg1] by user
[arg2] from [arg3] at IP address [arg4].
Informational
FQXSPEM4039I Attempting to perform an immediate dust filter measurement on
server [arg1] by user [arg2] from [arg3] at IP address [arg4].
Informational
FQXSPEM4041I The SmartNIC in slot [arg1] encountered boot timeout. Informational
FQXSPEM4042I The SmartNIC in slot [arg1] went through a crash dump. Informational
FQXSPEM4044I Dust filter measurement was successfully completed, no action is
needed.
Informational
FQXSPFC4000I
The bare metal connection process has been started. Informational
FQXSPFC4001I The bare metal update application reports a status of [arg1]. Informational
FQXSPFC4002I System running in setup. Informational
FQXSPFC4003I UEFI deployment boot mode is enabled for NextBoot. Informational
FQXSPFC4004I UEFI deployment boot mode is enabled for NextAc. Informational
FQXSPFC4005I
UEFI deployment boot mode has been disabled. Informational
FQXSPFW0003I The System [ComputerSystemElementName] encountered firmware
progress.
Informational
FQXSPIO0000I The connector [PhysicalConnectorElementName] has been detected
as present or connected.
Informational
FQXSPIO0010I A Correctable Bus Error has occurred on bus [SensorElementName]. Informational
Chapter 2. XClarity Controller events 11