FQXSFMA0050G: DRAM PFA threshold limit exceeded on DIMM [arg1] sub-channel [arg2] Rank
[arg3] DRAM [arg4], DIMM identifier is [arg5].
Severity: Warning
Parameters:
[arg1] DIMM Silk Label
[arg2] Sub Channel
[arg3] Rank number
[arg4] Device number (0&1&2)
[arg5] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Power off the system and remove the A/C power.
2. Reseat the affected DIMM.
3. Restore the A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
FQXSFMA0056I: Uncorrected memory error occurred on DIMM [arg1] has been deasserted after
performing post package repair. DIMM identifier is [arg2].
Severity: Info
Parameters:
[arg1] DIMM Silk Label
[arg2] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
FQXSFMA0057G: Page Retire PFA Threshold limit exceeded on DIMM [arg1] at address [arg2].
[arg3] [arg4]
Severity: Warning
Parameters:
[arg1] DIMM Silk Label, 1-based
[arg2] Address of the system where error occurred
[arg3] Page retire PFA policy reached, "-T0";"-T1";"-T2";"-T3";"-T4".
[arg4] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Power off the system and remove the A/C power.