2. Reseat the affected DIMM.
3. Restore the A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
FQXSFMA0065I: Multi-bit CE of DIMM [arg1] has been deasserted after performing post package
repair. DIMM identifier is [arg2].
Severity: Info
Parameters:
[arg1] DIMM Silk Label
[arg2] DIMM info (S/N, FRU and UDI)
User Action:
Information only; no action is required.
FQXSFMA0067G: Errors per row counter threshold limit exceeded on DIMM [arg1] sub-channel
[arg2] Rank [arg3] DRAM [arg4], need to restart the system for DIMM Self-healing to attempt post
package repair (PPR), DIMM identifier is [arg5].
Severity: Warning
Parameters:
[arg1] DIMM Silk Label
[arg2] Sub Channel
[arg3] Rank number
[arg5] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Restart the system to allow for DIMM Self-healing to attempt hard post package repair (PPR) and
confirm that event ID FQXSFMA0026I was recorded.
2. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
3. If the problem persists or if PPR attempt failed due to event ID FQXSFMA0027M or
FQXSFMA0028M, collect Service Data logs and contact Lenovo Support.
FQXSFMA0067I: Errors per row counter threshold limit exceeded on DIMM [arg1] has been
deasserted after performing post package repair. DIMM identifier is [arg2].
Severity: Info
Parameters:
[arg1] DIMM Silk Label
[arg2] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.