FQXSPUP4003I: [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the
[arg3] firmware.
This message is for the use case where a specific type of firmware mismatch has been detected.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0042
User Action:
Complete the following steps until the problem is solved:
1. AC cycle the system.
2. Reflash XCC/BMC firmware to the latest version.
3. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. If problem persists, collect Service Data log.
5. Contact Lenovo Support.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps and check XCC/BMC primary and backup firmware.
2. Check Lenovo support site for an applicable service bulletin or firmware update for the system or adapter that
applies to this error.
3. If problem persists, escalate to next level of support.
FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt
to flash the XCC firmware to the same level on all nodes/servers.
A mismatch of XCC firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0132
User Action:
Complete the following steps until the problem is solved:
1. Reflash XCC/BMC firmware to the latest version on all servers.
2. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.