EasyManua.ls Logo

Lenovo ThinkSystem SR850 V2 - Page 189

Lenovo ThinkSystem SR850 V2
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFPU4059I User requested to skip freezing lock of AHCI-attached SATA drives.
System UEFI accepted the request and will execute priot to OS boot.
Informational
FQXSFPU4060I Skipped freezing lock of AHCI-attached SATA drives. Informational
FQXSFPU4061I Restored default locking behavior of AHCI-attached SATA drives. Informational
FQXSFPU4080I Host Power-On password has been changed. Informational
FQXSFPU4081I Host Power-On password has been cleared. Informational
FQXSFPU4082I Host Admin password has been changed. Informational
FQXSFPU4083I Host Admin password has been cleared. Informational
FQXSFPU4084I
Host boot order has been changed. Informational
FQXSFPU4085I Host WOL boot order has been changed. Informational
FQXSFSM0007I The XCC System Event log (SEL) is full. Informational
FQXSFSR0002I [arg1] GPT corruption recovered, DiskGUID: [arg2] Informational
FQXSFDD0001G DRIVER HEALTH PROTOCOL: Missing Configuration. Requires
Change Settings From F1.
Warning
FQXSFDD0002M DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
Warning
FQXSFDD0003I DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller.
Warning
FQXSFDD0005M DRIVER HEALTH PROTOCOL: Disconnect Controller Failed. Requires
'Reboot'.
Warning
FQXSFDD0006M DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver. Warning
FQXSFDD0007G Security Key Lifecycle Manager (SKLM) IPMI Error.
Warning
FQXSFIO0008M
An intra-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
Warning
FQXSFIO0009M
An inter-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
Warning
FQXSFIO0013I The device found at Bus [arg1] Device [arg2] Function [arg3] could not
be configured due to resource constraints. The Vendor ID for the
device is [arg4] and the Device ID is [arg5]. The physical slot number
is [arg6].
Warning
FQXSFIO0016M IFM: Reset loop avoided - Multiple resets not allowed. Warning
FQXSFMA0012L The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at
address [arg3]. [arg4]
Warning
FQXSFMA0016M Memory spare copy failed. [arg1]
Warning
FQXSFMA0027M DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
Warning
FQXSFMA0028M DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
Warning
Chapter 3. UEFI events 185

Other manuals for Lenovo ThinkSystem SR850 V2

Related product manuals