Service Action:
Complete the following steps:
1. Review PD Steps.
2. Verify as-build configuration.
3. If processor is valid, inspect processor socket. If socket is damaged, replace the system board.
4. If problem persists, escalate to next level support.
FQXSFIO0010M: An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is
[arg6].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Verify PD Steps.
2. Rremove the adapter and confirm that the system reboots successfully without an adapter, replace PCIe
adapter.
3. If problem persists, escalate to next level support.
FQXSFIO0011M: A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function [arg3]. The
Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Verify PD Steps.
2. Replace the PCIe adapter.
3. If problem persists, escalate to next level support.
Chapter 3. UEFI events 195