Page #9 background imageLoading...
Page #9 background image
Table 1. Events that automatically notify Support (continued)
Event ID
Message String
FQXSPIO0011N An Uncorrectable Error has occurred on [SensorElementName].
FQXSPIO0015M Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
FQXSPMA0007L Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
FQXSPMA0008N Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
FQXSPMA0011G Memory Logging Limit Reached for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
FQXSPPU0004M [ProcessorElementName] has Failed with FRB1/BIST condition.
FQXSPPW0002L [PowerSupplyElementName] has Failed.
FQXSPPW0035M Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
FQXSPPW0047M Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
FQXSPSD0001L The [StorageVolumeElementName] has been disabled due to a detected fault.
FQXSPSD0002G Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
FQXSPSD0002L Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has been disabled due
to a detected fault.
FQXSPSD0003G Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
FQXSPSD0006L Array [ComputerSystemElementName] has failed.
FQXSPSD0008L Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
FQXSPSS4004I Test Call Home Generated by user [arg1].
FQXSPSS4005I Manual Call Home by user [arg1]: [arg2].
XCC events organized by severity
The following table lists all XCC events, organized by severity (Information, Error, and Warning).
Table 2. Events organized by severity
Event ID
Message String
Severity
FQXSPBR4000I Management Controller [arg1]: Configuration restored from a file by
user [arg2].
Informational
FQXSPBR4002I Management Controller [arg1] Reset was caused by restoring default
values.
Informational
FQXSPBR4004I Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2],
OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4],
LoaderTimeout=[arg5].
Informational
FQXSPBR4005I Management Controller [arg1]: Configuration saved to a file by user
[arg2].
Informational
Chapter 2. XClarity Controller events 5

Other manuals for Lenovo ThinkSystem SR850 V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenovo ThinkSystem SR850 V2 and is the answer not in the manual?

Lenovo ThinkSystem SR850 V2 Specifications

General IconGeneral
ProcessorUp to four 3rd Gen Intel Xeon Scalable processors
StorageUp to 24x 2.5" SAS/SATA HDDs/SSDs
Network InterfaceIntegrated 4 x 1GbE
Power Supply1600W Platinum or Titanium
Form Factor4U rack server
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementLenovo XClarity Controller

Related product manuals