EasyManua.ls Logo

Lenovo ThinkSystem SR950 V3 - Page 154

Lenovo ThinkSystem SR950 V3
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters:
[arg1]: slot/bay label name in system
User Action:
Complete the following steps:
1. Power down the server.
2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
FQXSFIO0005I: An intra-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
Parameters:
[arg1]: Socket number, 1-based [arg2]: Port Number [arg3]: Socket number, 1-based [arg4]: Port Number
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFIO0005M / FQXSFIO0006M event denoting some
UPI links failure which caused UPI topology downgrade.
2. Solve the event FQXSFIO0005M / FQXSFIO0006M at first, then this event should be solved
automatically.
3. If no recent or after fixing FQXSFIO0005M / FQXSFIO0006M event, this event still persists, collect
Service Data logs and contact Lenovo Support.
FQXSFIO0005M: An intra-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
Parameters:
[arg1]: Socket number, 1-based [arg2]: Port Number [arg3]: Socket number, 1-based [arg4]: Port Number
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
FQXSFIO0006I: An inter-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
Parameters:
[arg1]: Socket number, 1-based [arg2]: Port Number [arg3]: Socket number, 1-based [arg4]: Port Number
User Action:
Complete the following steps:
150