[arg1] :Unqualified/Non Lenovo [arg2]: Dimm Silk Label, 1-based [arg3]: Dimm serial number.
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does have unqualified memory
installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Contact your Local Sales Representative or Authorized Business Partner to order qualified memory
to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]
Severity: Info
Parameters:
[arg1] :Unqualified/Non Lenovo [arg2]: Dimm Silk Label, 1-based [arg3]: DIMM info (S/N, FRU and UDI.), e.
g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFMA0006I event denoting the server does have
unqualified memory installed.
2. Information only; no action is required.
FQXSFMA0008I: DIMM [arg1] POST memory test failure has been recovered. [arg2]
Severity: Info
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
Information only; no action is required.
FQXSFMA0008M: DIMM [arg1] has failed the POST memory test. [arg2]
Severity: Error
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.