EasyManua.ls Logo

Lenovo ThinkSystem SR950 V3 - Page 29

Lenovo ThinkSystem SR950 V3
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPUN0019M Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPUN0023N Sensor [SensorElementName] has transitioned to non-recoverable. Error
FQXSPUP0007L Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName].
Error
FQXSPUP4000I Please ensure that the Management Controller [arg1] is flashed with
the correct firmware. The Management Controller is unable to match
its firmware to the server.
Error
FQXSPUP4003I [arg1] firmware mismatch internal to system [arg2]. Please attempt to
flash the [arg3] firmware.
Error
FQXSPUP4004I XCC firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the XCC firmware to the same level on all
nodes/servers.
Error
FQXSPUP4005I FPGA firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the FPGA firmware to the same level on all
nodes/servers.
Error
List of XClarity Controller events
This section lists all messages that can be sent from the XClarity Controller.
FQXSPBR4000I: Management Controller [arg1]: Configuration restored from a file by user [arg2].
This message is for the use case where a user restores a Management Controller configuration from a file.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0027
User Action:
Information only; no action is required.
FQXSPBR4001I: Running the backup Management Controller [arg1] main application.
This message is for the use case where a Management Controller has resorted to running the backup
main application.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0030
User Action:
Complete the following steps until the problem is solved:
1. Update the BMC firmware.
Chapter 2. XClarity Controller events 25