User Action:
Complete the following steps until the problem is solved:
1. Information only; no action is required.
2. Note: This event will be set to Warning Severity for the LAN on Motherboard (LOM) interface and
Informational Severity for all other Network Adapters present where link status can be monitored.
• FQXSPEA2001I: Sensor [SensorElementName] has deasserted the transition from normal to non-
critical state.
This message is for the use case when an implementation has detected that a Sensor has deasserted a
transition to non-critical from normal.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0521
User Action:
Use storcli or LSA to check if there is any warning or critical RAID event.
• FQXSPEA2002I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0523
User Action:
Use Storcli or LSA to check if there is any warning or critical RAID event.
• FQXSPEM4000I: The [arg1] on system [arg2] cleared by user [arg3].
This message is for the use case where a Management Controller Event Log on a system is cleared by a
user.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0020
User Action:
Information only; no action is required.
• FQXSPEM4001I: The [arg1] on system [arg2] is 75% full.
This message is for the use case where a Management Controller Event Log on a system is 75% full.
Severity: Info
Serviceable: No
Chapter 2. XClarity Controller events 39