Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0224
User Action:
Complete the following steps:
1. Please reseat the processor and reboot the server.
2. If the problem still exist, (service technician) please replace the system board.
3. If the problem still exist, contact Lenovo support.
FQXSPIO0006N: A software NMI has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Software NMI.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0228
User Action:
Check the event log in system event log to resolve any issues related the NMI
FQXSPIO0007N: A PCI PERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI PERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0232
User Action:
Complete the following steps to solve:
1. Reseat the adapter or other slot.
2. If the problem still exist then replace the adapter.
3. If the problem still exist then contact local service.
FQXSPIO0008N: A PCI SERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI SERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0234
User Action:
Chapter 2. XClarity Controller events 51