S94P01C -e1
59
  4.  Make sure that “Enable Accel/Decel limits” is set to “Disable”.   
  5.  From the node tree, select  “Indexer program”.  The drives current program 
will appear in the View Window. Click anywhere in the View Window to 
activate the tool bar. From the MotionView menu select <Indexer>, <Import 
program from file>.  Navigate to the following folder MotionView6.xx/Help/
940Examples.  Select the TuneV program and click Open.  Click on the 
compile and download button on the toolbar to load the program to the drive.
  6.
  Select “Oscilloscope” tool  from the node tree to engage the oscilloscope. 
Check checkbox “Always on top”, so MotionView main window doesn’t cover 
the oscilloscope tool.
  7.  On the Scope tool select:
    •  Channel 1:   “Motor Velocity” 
    •  Scale:     100 Rpm/Volt
    •  Channel 2:   “Phase Current (RMS)”
    •  Scale:     Motor peak current parameter / 3 
    •  Timebase:    50mS
    •  Trigger:   Channel 1, Rising
    •  Trigger level:   100 Rpm
     (Choose closest integer value: if 10A/3=3.33(3) choose 3A)
  8.  Select “Compensation” from the Node tree. As a starting point, set “Gain 
Setting” to “-2” if the motor is equipped with an encoder.  If the motor is 
equipped with a resolver, set this to “-4”.  Refer to Section 6.9.8 for more 
details.
  9.
  Set the Velocity P-gain to 5000 and the Velocity I-gain to 20.
10.  Apply voltage to IN_A3 input and press F5 on the keyboard. Alternatively you 
can use menu “Indexer” -> “Run” or use button on the toolbar.
11.  If the motor vibrates uncontrollably, disable the drive, rest P-Gain to 1000, 
and re-enable the drive.
12.  Slowly increase the “Velocity P-gain” and observe the motor velocity 
waveform. Increasing the P-gain should increase the angle of the 
acceleration edge of the wave form. Continue increasing the P-gain to get 
the leading edge of the wave form as vertical as possible and stop once 
you start to get a slight overshoot. The current wave form should be spiking 
during the acceleration segment of the move. Continue to increase the P-gain 
until instability starts to appear in the waveform. 
 
 
S949