3 System Description
EDBC250SBC |1.1
l
ll
l
16
3.4 System Power Supply
3.4.1 General
Multipole connectors stand for high port density in a confined space.
Release latches facilitate the separation of the plug connection in tight spaces.
Screw flanges ensure for a snug fit, if the plugs are small
Spring-assisted plugs ensure quick and easy wiring.
1-row: Tool: Screwdriver blade 0,4 x 2,5 x 75 (DIN 5264-A)
Wires: 320V/ 10 A/ 0.2 – 1.5 m (IEC)
Rated current: 300V/ 10 A/ 28 - 14 AWG (UL)
Connectable conductors with ferrules:
Conductor cross ssection
[mm
2
]
Type of core end sleeve
0,13
0,25
0,34
0,50
0,75
1
1,5
with collar to DIN 46 228/4
8 / 10
8 / 10
8 / 10
without collar to DIN 46 228/1
8 / 10
8 / 10
8 / 10
Stripping length [mm] / sleeve length [mm]
The Push-in spring connector enables fast, tool-free wire connection by direct plug-in
technology. The stripped solid wires or flexible wires with crimped ferrules are plugged all the
way into the terminal point.
2-row: Wires: 320V/ 13.4 A/ 0.14 – 1.5 mm² (IEC)
Rated current: 300V/ 9.5A/ 26 - 16 AWG (UL)
Connectable conductors with ferrules:
Conductor cross ssection
[mm2]
Type of core end sleeve
0,14
0,25
0,34
0,50
0,75
1
1,5
with collar to DIN 46 228/4
8 / 10
8 / 10
8 / 10
10 / 12
12 / 14
12 / 15
without collar to DIN 46 228/1
10 / 10
Stripping length [mm] / sleeve length [mm]
NOTE
The power supply lines may not be connected by one supply terminal of the
Lenze Safety Module to the next. In order to ensure trouble-free operation, the
supply lines must be routed in star formation with the shortest possible lines
from a central supply terminal to Lenze Safety Module.