Operating Instructions
EDB82MV752
.5eI
Global Drive
8200 motec frequency inverter
0.25 kW ... 7.5 kW
Ä.5eIä

Table of Contents

Questions and Answers

  • J
    Jennifer TaylorSep 8, 2025
    What to do if Lenze DC Drives motor does not rotate because wrong parameter set is active?
    • J
      Jennifer LewisSep 8, 2025
      If the Lenze DC Drives motor does not rotate and the wrong parameter set is active, change to the correct parameter set via terminal.
  • S
    sharon60Sep 10, 2025
    What to do if Lenze DC Drives motor does not rotate because no motor parameter identification executed?
    • Y
      Yvette RichSep 10, 2025
      If the Lenze DC Drives motor does not rotate and the operating mode C0014 = '4' or '5', but no motor parameter identification has been executed, perform motor parameter identification (C0148).
  • M
    Meagan MendezSep 12, 2025
    What to do if Lenze DC Drives motor does not rotate because of conflicting functions assigned to the same signal source?
    • S
      Sandra HendersonSep 12, 2025
      If the Lenze DC Drives motor does not rotate and several mutually exclusive functions are assigned to the same signal source under C0410, correct the configuration in C0410.
  • L
    Lori AllisonSep 13, 2025
    What to do if Lenze DC Drives motor does not rotate because of missing jumper?
    • R
      Richard DominguezSep 14, 2025
      If the Lenze DC Drives motor does not rotate and you are using the internal voltage source X3/20 for function modules Standard I/O, INTERBUS, PROFIBUS-DP, or LECOM-B (RS485), ensure that the jumper between X3/7 and X3/39 is present. If it's missing, jumper the terminals.
  • M
    Mrs. Brenda SheltonSep 15, 2025
    What to do if Lenze DC Drives motor does not rotate smoothly because motor underexcited or overexcited?
    • C
      Carolyn RichardsonSep 15, 2025
      If the Lenze DC Drives motor does not rotate smoothly, and the motor is either underexcited or overexcited, check the parameter settings (C0015, C0016, C0014).
  • M
    Matthew MarquezSep 18, 2025
    What to do if Lenze DC Drives motor does not rotate smoothly because of incorrect parameters?
    • K
      Kristin WilliamsonSep 18, 2025
      If the Lenze DC Drives motor does not rotate smoothly, and parameters C0084, C0087, C0088, C0089, C0090, C0091, and/or C0092 are not adapted to the motor data, perform manual adaptation or identification of motor parameters (C0148).

Summary

Safety information

General safety and application instructions for Lenze controllers

Provides essential safety guidelines for handling, installation, and operation of Lenze controllers to prevent injury and damage, covering general safety and application as directed.

General safety and application instructions for Lenze motors

Details safety precautions for Lenze low-voltage motors, covering general safety, application as directed, transport, storage, and installation.

Residual hazards

Identifies potential residual hazards associated with the controller, including electrical voltage, heatsink temperature, device protection, and overspeed risks.

Technical data

Rated data at a mains voltage of 230 V

Provides detailed rated electrical data for the 8200 motec inverter at 230 V mains voltage, including currents, output voltage, power loss, dimensions, and fuses.

Installation

Electrical installation

Details crucial electrical installation procedures, including safety, EMC requirements, earth-leakage circuit breakers, cable specifications, power, and control connections.

Commissioning

Parameter setting

Parameter setting via keypad

Explains how to set parameters using the E82ZBB diagnosis terminal, covering installation, displays, functions, menu structure, and key operations.

Function library

Configuration of analog and digital setpoints and actual values

Covers configuring analog and digital setpoints, including source selection, scaling, and signal linkage for inputs and outputs, with examples for process control.

Automatic detection of motor data

Details the procedure for automatically detecting motor data, crucial for vector and sensorless torque control, and correcting data during operation to optimize performance.

Troubleshooting and fault elimination

Error elimination

Provides a systematic approach to eliminating drive maloperations by identifying faults, causes, and remedies, covering common issues like motor not rotating or smooth running.

Braking operation

Application examples

Appendix

Code table

Provides a detailed table of all codes, their meanings, possible settings, and important notes for parameter configuration, covering various functions and modules.

Table of attributes

Lists table of attributes required for writing custom programs, including code, index, data structure, format, and access rights for standard devices.

Lenze E82MV751_4B Specifications

General IconGeneral
BrandLenze
ModelE82MV751_4B
CategoryDC Drives
LanguageEnglish

Related product manuals