Technical data
Electrical data
3
39
EDK94PNE36 DE/EN/FR/ES/IT 2.0
3.2 Electrical data
Basis of the data
Mains Rated voltage U
LN
[V]
Voltage range U
LN
[V]
Frequency range
[Hz]
3/PE AC 230 180-0%...264+0% 45 ... 65
3/PE AC 400 320-0%...440+0% 45 ... 65
3/PE AC 500 400-0%...550+0% 45 ... 65
Input data
Voltage Frequency Current [A] Current [A]
Number
of phases
Type [V] [Hz] c max. +45° C c max. +55° C
E94APNE0104 230/400/500 50/60 8/8/8 6/6/6 3
E94APNE0364 230/400/500 50/60 29/29/29 21.8/21.8/21.8 3
c Ambient temperature in the control cabinet
Voltage Continuous input power
Type [V] S
L
[kVA]
E94APNE0104 230/400/500 3.2/5.5/6.9
E94APNE0364 230/400/500 11.5/20.1/25.1
Output data
Voltage Frequency Current [A] Current [A]
Number
of phases
Type [V] [Hz] c max. +45° C c max. +55° C
E94APNE0104 325/565/705 0(DC) 10/10/10 7.5/7.5/7.5 2
E94APNE0364 325/565/705 0(DC) 36/36/36 27/27/27 2
c Ambient temperature in the control cabinet
Voltage Output power X109, X110, +UG, -UG
Type [V] With mains filter P
aDC
[kW] Without mains filter P
aDC
[kW]
E94APNE0104 325/565/705 2.8/4.8/6.0 2.1/3.6/4.5
E94APNE0364 325/565/705 10.1/17.5/21.8 7.5/13.0/16.2
Power loss P
V
[W]
Type Total (when operating with I
aNx
) Constant (control electronics only)
E94APNE0104 55 5
E94APNE0364 110 5