Technical data
General data and operating conditions
EDK10203EZ3 DE/EN/FR 4.1
13
H1_Daten−All_Data_Ext−board_en
3 Technical data
General data and operating conditions
Conformity CE Low−Voltage Directive (2006/95/EC)
Approvals UL 508C Underwriter Laboratories (File−No. E132659)
Power Conversion Equipment
DC supply voltage
Voltage external +18 VDC −0 % ... +30 VDC +0 %
Current max. 4 A
(at max. load of all outputs)
Climatic conditions Class 3K3 to EN 50178
(without condensation, average relative humidity 85 %)
Temperature range
Transport −25 °C ...+70 °C
storage −25 °C ...+60 °C
Operation 0 °C ... +40 °C without power derating
+40 °C ... +55 °C with power derating
Power derating of output currents for t
a
> +40 °C: 2.5 %/K
Vibration resistance Resistant to acceleration up to 0.7 g
Permissible mounting
positions
in the Drive PLC on a plug−in−station for extension board
Insulation voltage to PE 50 V AC
Enclosure IP 20
Digital inputs
Level LOW (0 V ...+4 V)
HIGH (+13 V ...+30 V)
Input current 8 mA at 24 V
Digital outputs
Level LOW (0 V ...+4 V)
HIGH (+13 V ...+30 V)
Load capacity max. 1 A per output
Analog inputs
Input voltage −10 V ... +10 V
Resolution 10 bit + sign
Incremental encoder/
meter input
Connection SubD bush, 9−pole
HTL level Input frequency: 0 − 200 kHz
Current input per channel: 5 mA
TTL level Input frequency: 0 − 500 kHz
Current input per channel: 6 mA
Current input at pin 4 (V
CC5_E
): max. 150 mA
Dimensions
Height 145 mm (incl. terminal strips)
Width 72 mm
Depth 35 mm