Implemented CIP™ objects
EtherNet/IP objects
132
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Instance attribute "Control Bits" (attribute 6, Interface Control)
Supported service codes
Bits Name Description
0 Auto-negotiate Activation of "Link Auto-Negotiation"
0: "Link Auto-Negotiation" is not active.
The device uses the settings of the bits "Forced Duplex Mode" (bit 1)
and "Forced Interface Speed" (see attribute 6, Interface Control).
1: "Link Auto-Negotiation" is active.
1 Forced Duplex Mode If "Auto-negotiate" bit = 0, this bit indicates the transmission mode to be
used.
•0: Half duplex
1: Full duplex
2 ... 15 - Reserved (0)
Service code
[hex]
Name Description
0x01 Get_Attributes_All Outputs a list of the attributes and the attribute's values for
a certain object.
0x0E Get_Attribute_Single Outputs the value of a certain attribute.
0x10 Set_Attribute_Single Changes the value of a certain attribute.

Table of Contents