Lenze EtherNet/IP E84DGFCGFNP Specifications

General IconGeneral
BrandLenze
ModelEtherNet/IP E84DGFCGFNP
CategoryConference System
LanguageEnglish

Summary

About this documentation

Document history

Provides a record of changes and revisions made to the documentation over time.

Conventions used

Explains the highlighting, symbols, and formatting conventions used throughout the manual.

Terminology used

Defines key terms and acronyms related to EtherNet/IP and the Inverter Drive 8400 motec.

Notes used

Details the signal words and pictograms used to indicate important information and dangers.

Safety instructions

General safety and application notes

Outlines essential safety measures and guidelines for the proper use and application of the device.

Device and application-specific safety instructions

Provides safety information specific to the device and its intended applications.

Residual hazards

Identifies potential risks and hazards that may remain even after safety measures are applied.

Product description

Application as directed

Defines the intended use and operational scope of the EtherNet/IP Communication Unit.

Features and variants

Details the available versions, features, and technical specifications of the communication unit.

Connections and interfaces

Describes the physical connections and interfaces on the EtherNet/IP Communication Unit.

Technical data

General data and operating conditions

Presents general specifications and environmental conditions for the communication unit.

Protocol data

Details protocol-specific data, including supported CIP services and I/O data.

Communication time

Explains communication times and processing times within the inverter and module.

Internal switch latency

Describes runtime delays caused by the integrated 2-port switch.

Installation

Mechanical installation

Provides instructions and diagrams for the physical mounting of the Inverter Drive 8400 motec components.

Electrical installation

Covers the electrical wiring and setup, including network topology.

Network topology

Describes supported EtherNet/IP network topologies like line, star, and tree.

EtherNet;IP connection

Details the M12 socket and wiring for the EtherNet/IP connection.

External voltage supply

Explains the use and wiring of an external voltage supply for commissioning and backup.

Commissioning

Before initial switch-on

Specifies pre-commissioning checks, including wiring verification.

Configuring the host system (scanner)

Guides on configuring the host system (scanner) for EtherNet/IP communication.

EDS files

Explains the role and usage of Electronic Data Sheet (EDS) files for configuration.

Example: IP configuration of the Allen-Bradley 1769-L32 E Compactlogix controller

Provides a step-by-step example for setting IP configuration on an Allen-Bradley controller.

Setting the IP configuration of the Inverter Drive 8400 motec

Details methods for setting the IP address, subnet mask, and gateway for the inverter.

Setting via the EtherNet;IP configurator of the Engineer

Describes how to set IP parameters using the Lenze »Engineer« software.

Setting via codes in the Engineer

Explains manual IP parameter configuration using codes within the »Engineer« software.

Setting via a BOOTP;DHCP server

Describes how to assign IP addresses dynamically using BOOTP or DHCP servers.

Setting via the TCP;IP Interface Object (0 xF5)

Details setting IP configuration via the TCP/IP Interface Object.

Setting the multicast configuration

Explains settings for multicast IP addressing and TTL values.

Establishing an online connection via EtherNet;IP with the Lenze Engineer

Guides on establishing an online connection between the »Engineer« and the inverter.

Initial switch-on

Provides instructions for the initial power-up and communication establishment.

Data transfer

Communication channels

Explains the two main communication channels: I/O data and parameter data.

Telegram types

Describes the 'implicit message' and 'explicit message' telegram types used for data transfer.

EtherNet;IP state diagram

Illustrates the EtherNet/IP device states and transitions.

I;O data transfer (implicit messages)

Configuring I;O data

Details how to specify and configure I/O data during scanner initialization.

I;O data mapping

Explains how I/O data is transferred via the MCI interface and port blocks.

Technology applications (TA); drive profiles

Describes supported drive profiles that define control and status word assignments.

Lenze technology applications; user-definable parameter sets

Explains Lenze technology applications and custom parameter set configuration.

AC Drive Profile application

Details the EtherNet/IP-specific 'AC Drive Profile' and its assembly object instances.

I;O assemblies

Covers supported assembly objects for data exchange, including input and output.

I;O configuration in the Engineer

Guides on configuring I/O data using the Lenze »Engineer« software.

Lenze technology application; configuring user-definable parameter sets

Details configuring Lenze technology applications and user-definable parameter sets.

Configuring AC Drive Profile application

Explains how to configure the 'AC Drive Profile' application within the »Engineer«.

I;O configuration with RSLogix 5000 version 19 or lower

Step-by-step guide for I/O configuration using RSLogix 5000 (versions 19 and below).

I;O configuration with RSLogix 5000 version 20 or higher

Step-by-step guide for I/O configuration using RSLogix 5000 (versions 20 and above).

Saving the I;O configuration in RSLogix 5000

Instructions on how to save the I/O configuration project in RSLogix 5000.

Parameter data transfer (explicit messages)

Write parameters

Details how to write parameters to the Inverter Drive using explicit message transfer.

Read parameters

Explains how to read parameters from the Inverter Drive using explicit message transfer.

Monitoring

Fault with regard to EtherNet;IP communication

Describes how to set monitoring responses for EtherNet/IP communication faults.

Diagnostics

LED status displays

Explains the meaning of the LED indicators on the Communication Unit for status.

Diagnosing with the Engineer

Details how to use the »Engineer« software for EtherNet/IP diagnostics.

Error messages

Short overview of the EtherNet;IP error messages

Lists EtherNet/IP error numbers, text, types, and adjustable parameters.

Possible causes and remedies

Provides detailed causes and remedies for various EtherNet/IP error messages.

CIP error messages

Lists common CIP™ error codes and their descriptions.

Mapping of Lenze device errors to DRIVECOM errors

Correlates Lenze device errors with DRIVECOM error numbers and messages.

Parameter reference

Parameters of the Communication Unit

Lists and describes parameters specific to the EtherNet/IP Communication Unit.

Table of attributes

Explains the structure and meaning of attributes used for parameter access.

Implemented CIP objects

Overview of the implemented CIP objects

Provides a summary of the CIP objects implemented by Lenze.

General CIP objects

Details general CIP objects like Identity, Message Router, Assembly, and Connection Manager.

EtherNet;IP objects

Describes EtherNet/IP specific CIP objects like DLR, QoS, TCP/IP Interface, and Ethernet Link.

AC Drive Profile objects

Details CIP objects related to the 'AC Drive Profile' for motor control.

Lenze objects

Describes Lenze-specific CIP objects for error responses and data mapping.