Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019 17
Product description
Connections and interfaces
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
By default, the EtherNet/IP connections and the LEDs for the EtherNet/IP status displays are
already mounted and wired:
EtherNet/IP connection A2 to plug connector X31
EtherNet/IP connection A3 to plug connector X32
LEDs on plug connector X55
At positions A1 ... A4 and B1 ... B4, it is also possible to design the EtherNet/IP connections and
other connections (e.g. digital inputs) freely.
For the connections, 5-pin M12 connectors or - alternatively - cable glands (cable cross-section
max. 1.0 mm
2
, AWG 18) can be used.
The M12 connectors, cable glands and prefabricated system cables can be obtained from
various manufacturers.
Wire the M12 connectors or cable glands used to the corresponding contacts of the terminal
strips/plug connectors X3, X4 and X61.