EDB8210UE-V020
400753
Operating Instructions
Global Drive
Frequency Inverters
8210 HVAC Series
HVACandPumpDrives
Power Range 0.75 - 11 kW
Typ
Id.-NR
Fert.-Nr
Serien-Nr.
Eingang1
Eingang2
Lenze
Postfach 101352 ,31763 HAMELN
Typ
Id.-NR
Fert.-Nr
Serien-Nr.
Eingang1
Eingang2
Lenze
Postfach 101352 ,31763 HAMELN
Show/Hide Bookmarks

Table of Contents

Questions and Answers

  • S
    shannonwilliamsonSep 8, 2025
    Why is the current consumption of my Lenze EVF8216-EV020 DC Drives motor too high?
    • W
      whitestefanieSep 8, 2025
      High current consumption in the motor can be attributed to a few settings. The setting of C016 might be too high, or the setting of C015 might be too low. Additionally, C088 and C091 might not be adapted to the motor data.
  • J
    Jessica CooperSep 10, 2025
    What causes grounded motor phase in Lenze EVF8216-EV020?
    • T
      Tony LiSep 10, 2025
      A grounded motor phase can be caused by a grounded motor phase. Check the motor and cable. Also, excessive capacitive charging current of the motor cable can lead to a grounded motor phase; use a motor cable which is shorter or of lower capacitance.
  • N
    Nathaniel CummingsSep 12, 2025
    Why is my Lenze DC Drives motor not rotating smoothly?
    • C
      Crystal CunninghamSep 12, 2025
      If the motor isn't rotating smoothly, it could be due to a defective motor cable. The maximum current C022 and C023 might also be set too low. Another possibility is that the motor is underexcited or overexcited; check the parameter setting.
  • M
    Margaret WagnerSep 13, 2025
    What to do if mains voltage is too high in Lenze DC Drives?
    • A
      Annette FarrellSep 13, 2025
      If the mains voltage is too high, check the voltage supply. It could also be due to feedback operation during braking. Increase deceleration times. For operation with brake choppers, check the selection and connection of the brake resistor and increase the deceleration times. Another cause may be Earth leakage on the motor side, check motor cable and motor for earth fault (disconnect motor from inverter).
  • W
    webbchristieSep 15, 2025
    What causes faulty parameter transfer via the operating module in Lenze EVF8216-EV020?
    • S
      Sharon MaySep 15, 2025
      If PAR1 and PAR2 are defective, it can cause a faulty parameter transfer. It is absolutely necessary to repeat the data transfer or load the factory setting before enabling the controller.
  • N
    nlewisSep 18, 2025
    What causes faulty auto-TRIP reset in Lenze DC Drives?
    • C
      Christopher DicksonSep 18, 2025
      Faulty auto-TRIP reset is caused by more than 8 fault messages in 10 minutes. The solution depends on the fault message.

Summary

Preface and general information

About these Operating Instructions

Details the purpose, scope, and key terms of the manual.

Scope of delivery

Lists the components included in the product delivery.

Legal regulations

Covers legal requirements and directives applicable to the product.

Safety information

General safety information

Provides essential safety and application notes for controller operation.

Layout of the safety information

Explains the structure and meaning of safety symbols and signal words.

Residual hazards

Identifies potential residual hazards associated with the controller.

Technical data

General data;application conditions

Specifies general operating conditions, environmental limits, and approvals.

Rated data (Operation with 120% overload)

Provides electrical ratings for operation with 120% overload.

Fuses and cable cross-sections

Specifies recommended fuses and cable cross-sections for protection.

Installation

Mechanical installation

Covers important notes and procedures for physical mounting.

Electrical Installation

Covers important notes and procedures for electrical connections.

Installation of a CE-typical drive system

Guidance for installing a drive system to meet CE requirements.

Commissioning

Before you switch on

Pre-commissioning checks for wiring and connections.

Adapt machine data

Instructions for adjusting machine parameters for optimal performance.

Optimisation of the operating characteristic of the drive

Settings to influence current, torque, and power characteristics.

During operation

Configuration

Basics

Introduction to controller configuration and parameter organization.

Code table

Explains how to read and interpret the code tables for parameters.

Troubleshooting and fault elimination

Troubleshooting

Methods for identifying and diagnosing faults using display elements.

Fault analysis using the history buffer

Using the history buffer to trace fault messages in order of occurrence.

Fault indications

Provides a list of fault displays, their causes, and remedies.

Accessories (Overview)

Accessories for all types

Lists general accessories applicable to all controller types.

Type-specific accessories

Lists accessories specific to different controller types.

Index

Lenze EVF8216-EV020 Specifications

General IconGeneral
BrandLenze
ModelEVF8216-EV020
CategoryDC Drives
LanguageEnglish