EDB8210UE-V020
400753
Operating Instructions
Global Drive
Frequency Inverters
8210 HVAC Series
HVACandPumpDrives
Power Range 0.75 - 11 kW
Typ
Id.-NR
Fert.-Nr
Serien-Nr.
Eingang1
Eingang2
Lenze
Postfach 101352 ,31763 HAMELN
Typ
Id.-NR
Fert.-Nr
Serien-Nr.
Eingang1
Eingang2
Lenze
Postfach 101352 ,31763 HAMELN
Show/Hide Bookmarks

Table of Contents

Questions and Answers

  • T
    tkellyAug 20, 2025
    What causes overload inverter during acceleration or short circuit in Lenze EVF8215-EV020?
    • S
      ssmithAug 20, 2025
      An overload during acceleration or a short circuit can occur if the acceleration time (C012) is too short. In this case, increase the acceleration time and check the drive selection. A defective motor cable can also cause this, so check the wiring. Finally, an interturn fault in the motor itself could be the issue, so check the motor.
  • T
    thomas54Aug 22, 2025
    What causes overload controller during deceleration in Lenze DC Drives?
    • L
      Lauren SmithAug 22, 2025
      An overload of the controller during deceleration is often due to a deceleration time (C013) that is too short. Increase the deceleration time and check the selection of the brake resistor or connect the brake chopper.
  • A
    Amy GlennAug 25, 2025
    What does I x t overload mean in Lenze EVF8215-EV020 DC Drives?
    • S
      snielsenAug 25, 2025
      I x t overload can be caused by frequent and too long acceleration processes with overcurrent. In this case, check drive dimensioning.
  • A
    Alvin MartinezAug 26, 2025
    What causes overload motor in Lenze EVF8215-EV020?
    • G
      george29Aug 26, 2025
      The motor can be overloaded if it's thermally overloaded, perhaps due to an impermissible continuous current. Check the drive selection. Frequent or overly long acceleration processes can also cause this; check the setting under C120.
  • J
    Jessica ThomasAug 27, 2025
    What causes PTC monitoring issues in Lenze DC Drives?
    • C
      Christine BakerAug 27, 2025
      PTC monitoring issues can arise if the motor is too hot due to excessive current or frequent and overly long acceleration. Check drive dimensioning. Also, the PTC might not be connected; connect the PTC or switch off monitoring (C0585=3).
  • J
    Jonathan TerryAug 29, 2025
    What does overtemperature unit mean for Lenze DC Drives?
    • C
      Casey DavisAug 29, 2025
      An overtemperature unit indicates that the inside of the unit is too hot. Reduce the controller load, improve cooling, and check the fan in the controller.
  • J
    Jonathan MontgomeryAug 31, 2025
    Why is my Lenze DC Drives motor not rotating?
    • K
      Keith Collins MDAug 31, 2025
      The motor might not be rotating due to several reasons: * The DC-bus voltage could be too low, indicated by a red LED blinking every 0.4 seconds and the message LU being displayed. * The controller might be inhibited, shown by a blinking green LED and the display showing OFF, STOP, or AS_LC. * Other potential causes include a setpoint of 0, active DC braking, an active quick-stop function, a JOG setpoint activated with JOG frequency set to 0, a fault message being displayed, or the mechanical motor brake not being released.
  • M
    mcculloughcrystalSep 2, 2025
    What to do if my Lenze EVF8215-EV020 unit overheats?
    • W
      wcollinsSep 2, 2025
      If the heat sink temperature is higher than the value set in the controller, it could be due to several factors. The ambient temperature (Tu) might be exceeding +40°C or +50°C. Allow the controller to cool and ensure proper ventilation, and check the ambient temperature in the control cabinet. The heat sink might also be dirty, so cleaning it could help. Finally, an incorrect mounting position could be the cause, so try changing it.
  • M
    Michael PowellSep 4, 2025
    What causes undervoltage in Lenze DC Drives?
    • H
      hineslindaSep 4, 2025
      Undervoltage can be caused by a DC-bus voltage that is too low. Check the mains voltage and the supply module.
  • A
    Angela WattsSep 6, 2025
    What causes short circuit in Lenze EVF8215-EV020 DC Drives?
    • C
      cesar19Sep 6, 2025
      A short circuit can be caused by a short circuit itself. Find out the cause of the short circuit and check the cable. Also, excessive capacitive charging current of the motor cable can lead to a short circuit; use a motor cable which is shorter or of lower capacitance.

Summary

Preface and General Information

About these Operating Instructions

Details on the purpose, scope, and mandatory observance of these instructions.

Terminology Used

Defines key terms and abbreviations used throughout the manual.

Changes in Operating Instructions

Lists revisions and updates made to the operating instructions.

Scope of Delivery

Specifies the components included in the product package upon delivery.

Legal Regulations

Outlines legal requirements, directives, and standards applicable to the product.

Safety Information

General Safety Information

Covers essential safety precautions for operation, installation, and maintenance.

Layout of Safety Information

Explains the structure and meaning of safety icons and signal words.

Residual Hazards

Highlights potential risks and hazards that may remain after initial safety measures.

Technical Data

General Data and Application Conditions

Provides environmental, physical, and general operating parameters.

Rated Data (120% Overload)

Specifies electrical and performance ratings for operation with 120% overload.

Rated Data (150% Overload)

Details electrical and performance ratings for operation with 150% overload.

Fuses and Cable Cross-sections

Recommends fuse types and cable sizes for safe and proper operation.

Analog Plug-in Module

Describes the features and functionality of the analog input module.

Dimensions

Presents physical dimensions of the controller and accessories.

Installation

Mechanical Installation

Guides on physical mounting, ventilation, and environmental considerations.

Electrical Installation

Details on wiring, connections, and electrical safety requirements.

Installation of a CE-Typical Drive System

Provides guidance for compliant installation to meet EMC directives.

Commissioning

Before You Switch On

Pre-checks and wiring verification steps before initial power-up.

Short Set-up (Factory Setting)

Outlines the basic steps for initial drive setup using factory defaults.

Adapt Machine Data

Instructions for configuring parameters specific to the connected motor and application.

Optimisation of Operating Characteristic

Guidance on selecting and tuning control modes for optimal performance.

Operation with PID Controller

Details on configuring and utilizing the internal PID controller for process control.

Application Examples

Illustrates typical configurations for air conditioning and pump control systems.

Signal-flow Charts

Visual representations of internal signal processing and control logic.

During Operation

Configuration

Basics

Introduction to controller configuration and parameter organization.

Code Table

Explains the structure and meaning of the parameter codes used for configuration.

Troubleshooting and Fault Elimination

Troubleshooting

Methods for diagnosing issues via controller LEDs and operating module displays.

Fault Analysis Using History Buffer

Guidance on using the internal history buffer to trace and identify faults.

Fault Indications

Lists common fault displays, their causes, and recommended remedies.

Reset of Fault Indications

Procedures for acknowledging and resetting fault conditions and alarms.

Accessories (Overview)

Accessories for All Types

Lists general accessories and their order numbers applicable to all product variants.

Software

Information on available software tools for controller management and configuration.

Type-Specific Accessories

Details accessories specific to different model types (e.g., fuses, filters).

Lenze EVF8215-EV020 Specifications

General IconGeneral
Device CategoryDC Drives
ModelEVF8215-EV020
Output Power7.5 kW
Output Current20 A
Frequency Range50/60 Hz
Enclosure RatingIP20
Protection FeaturesOvervoltage, Undervoltage, Overtemperature
Communication InterfaceCANopen