  • J
    Javier JohnsonSep 8, 2025
    Why is the current consumption of my Lenze DC Drives motor too high?
    • C
      Christopher SmithSep 8, 2025
      High current consumption in the motor can be attributed to a few settings. The setting of C016 might be too high, or the setting of C015 might be too low. Additionally, C088 and C091 might not be adapted to the motor data.
  • W
    Wesley BurnsSep 10, 2025
    What causes grounded motor phase in Lenze DC Drives?
    • D
      debrarodriguezSep 10, 2025
      A grounded motor phase can be caused by a grounded motor phase. Check the motor and cable. Also, excessive capacitive charging current of the motor cable can lead to a grounded motor phase; use a motor cable which is shorter or of lower capacitance.
  • K
    kaylarichardsonSep 12, 2025
    Why is my Lenze EVF8215-EV020 DC Drives motor not rotating smoothly?
    • K
      Kendra MezaSep 12, 2025
      If the motor isn't rotating smoothly, it could be due to a defective motor cable. The maximum current C022 and C023 might also be set too low. Another possibility is that the motor is underexcited or overexcited; check the parameter setting.
  • M
    Michelle WeaverSep 13, 2025
    What to do if mains voltage is too high in Lenze DC Drives?
    • P
      Paul JohnsonSep 13, 2025
      If the mains voltage is too high, check the voltage supply. It could also be due to feedback operation during braking. Increase deceleration times. For operation with brake choppers, check the selection and connection of the brake resistor and increase the deceleration times. Another cause may be Earth leakage on the motor side, check motor cable and motor for earth fault (disconnect motor from inverter).
  • K
    Kelly MillerSep 15, 2025
    What causes faulty parameter transfer via the operating module in Lenze DC Drives?
    • Q
      qhuntSep 15, 2025
      If PAR1 and PAR2 are defective, it can cause a faulty parameter transfer. It is absolutely necessary to repeat the data transfer or load the factory setting before enabling the controller.
  • H
    hamiltonpaulaSep 17, 2025
    What causes faulty auto-TRIP reset in Lenze DC Drives?
    • S
      Samuel ChurchSep 18, 2025
      Faulty auto-TRIP reset is caused by more than 8 fault messages in 10 minutes. The solution depends on the fault message.

Summary

Preface and General Information

About these Operating Instructions

Details on the purpose, scope, and mandatory observance of these instructions.

Terminology Used

Defines key terms and abbreviations used throughout the manual.

Changes in Operating Instructions

Lists revisions and updates made to the operating instructions.

Scope of Delivery

Specifies the components included in the product package upon delivery.

Legal Regulations

Outlines legal requirements, directives, and standards applicable to the product.

Safety Information

General Safety Information

Covers essential safety precautions for operation, installation, and maintenance.

Layout of Safety Information

Explains the structure and meaning of safety icons and signal words.

Residual Hazards

Highlights potential risks and hazards that may remain after initial safety measures.

Technical Data

General Data and Application Conditions

Provides environmental, physical, and general operating parameters.

Rated Data (120% Overload)

Specifies electrical and performance ratings for operation with 120% overload.

Rated Data (150% Overload)

Details electrical and performance ratings for operation with 150% overload.

Fuses and Cable Cross-sections

Recommends fuse types and cable sizes for safe and proper operation.

Analog Plug-in Module

Describes the features and functionality of the analog input module.

Dimensions

Presents physical dimensions of the controller and accessories.

Installation

Mechanical Installation

Guides on physical mounting, ventilation, and environmental considerations.

Electrical Installation

Details on wiring, connections, and electrical safety requirements.

Installation of a CE-Typical Drive System

Provides guidance for compliant installation to meet EMC directives.

Commissioning

Before You Switch On

Pre-checks and wiring verification steps before initial power-up.

Short Set-up (Factory Setting)

Outlines the basic steps for initial drive setup using factory defaults.

Adapt Machine Data

Instructions for configuring parameters specific to the connected motor and application.

Optimisation of Operating Characteristic

Guidance on selecting and tuning control modes for optimal performance.

Operation with PID Controller

Details on configuring and utilizing the internal PID controller for process control.

Application Examples

Illustrates typical configurations for air conditioning and pump control systems.

Signal-flow Charts

Visual representations of internal signal processing and control logic.

During Operation

Configuration

Basics

Introduction to controller configuration and parameter organization.

Code Table

Explains the structure and meaning of the parameter codes used for configuration.

Troubleshooting and Fault Elimination

Troubleshooting

Methods for diagnosing issues via controller LEDs and operating module displays.

Fault Analysis Using History Buffer

Guidance on using the internal history buffer to trace and identify faults.

Fault Indications

Lists common fault displays, their causes, and recommended remedies.

Reset of Fault Indications

Procedures for acknowledging and resetting fault conditions and alarms.

Accessories (Overview)

Accessories for All Types

Lists general accessories and their order numbers applicable to all product variants.

Software

Information on available software tools for controller management and configuration.

Type-Specific Accessories

Details accessories specific to different model types (e.g., fuses, filters).

Lenze EVF8215-EV020 Specifications

General IconGeneral
Device CategoryDC Drives
ModelEVF8215-EV020
Output Power7.5 kW
Output Current20 A
Frequency Range50/60 Hz
Enclosure RatingIP20
Protection FeaturesOvervoltage, Undervoltage, Overtemperature
Communication InterfaceCANopen