EasyManua.ls Logo

Lenze g500-S2100 - Page 29

Lenze g500-S2100
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical installation
Mounting of g500 short/servo adapters with clamping connection
Maximum permissible load at the motor adapter
4
29
Lenze ¯ MA 12.0018 ¯ 4.1
8
7
2
Fig. 6 Assignment: Motor shaft, clamping ring and mounting hole
2 Bell housing 7 Clamping ring
8 Terminal screw
4. Afterwards, insert the wrench (9) into the terminal screw (8) of the clamping ring
(7) and leave it there (Fig. 7). The terminal screw (8) must only be tightened to
such a degree that the clamping ring (7) does not move but the shaft is not
tightened yet!
1.
3.
2.
1
9
3
Fig. 7 Mounting of motor and gearbox
1 Gearbox 9 Wrench
3 Motor
Stop!
If the motor shaft is provided with a keyway, align the motor shaft in
such a way that the keyway is located opposite to the terminal screw.

Table of Contents

Other manuals for Lenze g500-S2100

Related product manuals