GND
AI1
AI2
AO1
10V
24V
DI1
DI2
DI3
DI4
DI5
GND
DO1
NO
COM
NC
U/I
V1-0
*P201.01
(configured AI1 as standard
setpoint)
*P400.02
Preset 01 (*P450.01)
*P100.00 output frequency
*P103.00 current actual value
Default seng
*P400.04
*P400.13
Start
Reset error
Mark direcon of rotaon
Acvate preset (bit 0)
Acvate preset (bit 1)
DO1 acvated at
Release brake
Relay acvated at
Ready for operaon
Analog input 1
Analog input 2
Analog output 1
10 VDC supply for potenometer
24 VDC, 100 mA supply, reference for digital inputs
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital input 5
Digital output 1
GND for analog and digital signals
Relay NO contact
Relay centre contact
Relay NC contact
bit 1 bit 0
Preset frequency values
0
0
1
1
1
1
Preset 02 (*P450.02)
Preset 03 (*P450.03)
– Select standard setpoint source *P201.01.
– Run forwards/backwards [stac signals], start forwards/backwards [edge controlled]
– Enable quick stop *P400.03: Bring motor to a standsll in best me.
– Jog forwards *P400.10: Let motor rotate forwards with setpoint preset 05 (CW).
– Jog backwards *P400.11: Let motor rotate backwards with setpoint preset 06 (CCW).
Diagnoscs
P102.00 setpoint frequency [Hz]
P125.01 acve control source
P125.02 acve setpoint source
*P430.01 (0 ... 10 VDC signal)
*P430.02 — *P430.03
*P400.18
*P400.19
*P420.02
*P420.01
Inverter inhibited, no DC-bus voltage.
Inverter inhibited, warning acve.
Inverter inhibited, error acve.
Inverter enabled and motor rotang or quick stop is acve.
Inverter enabled and motor rotang, warning signalled.
Inverter enabled, quick stop as response to fault acve.
Ramp me too short or motor is running in generator
mode
DC-bus overvoltage warning
DC-bus undervoltage warning
DC-bus voltage too low for switch-on
Trigger/funcon incorrectly connected.
In the case of flexible I/O configuraon *P200.01,
Inverter enable *P400.01 or Start *P400.02 must
have been assigned to an I/O. Do not use Start
forwards/backwards and Run forwards/backwards
at the same me.
Automac start inhibited.
GND for analog and digital signals
EN-gb
range [Hz]:
config.: