Page #1 background image
> 3 s
GND
AI1
AI2
AO1
10V
24V
DI1
GND
AI1
AI2
AO1
10V
24V
DI1
DI2
DI3
DI4
DI5
P211.00
P430.03
P430.02 P430.02
P22
0.
0
0
P
2
21.
00
P210.00
AI1
GROUP 4
P420.XX
P420.02
CTRL
R F
V1-0
Group 3 – motor control
Group 4 – I/O seng
Group 5 – network seng
Group 6 – process controller
Group 7 – addional funcons
Group 8 – sequencer
Group 0 – favourites: Quick access to most important parameters (*)
Procedure during commissioning
1. Load default sengs: Set P700.01 = 1
2. Select language: P705.00 1 = English; 2 = German
3. Basic seng of V/f characterisc control:
*P208.01 Set the mains voltage
*P303.01 basic voltage = rated motor voltage
*P303.02 basic frequency = rated motor frequency
*P210.00 minimum frequency [Hz]
*P211.00 maximum frequency [Hz]
*P220.00 acceleraon me [s]
*P221.00 delay me [s]
*P430.02 analog input 1: Minimum frequency [Hz]
*P430.03 analog input 1: Maximum frequency [Hz]
Control of inverter by means of keypad
Define keypad as control source and setpoint source:
*P200.00 = 1 (keypad as control source)
*P201.01 = 1 (keypad as setpoint source)
Operaon:
Change direcon of rotaon
Change setpoint frequency
Start/stop motor
Connecon:
Define preset frequency values:
[Hz]
[Hz]
[Hz]
Connecon:
I/O terminals
or
Inverter i410 - Quick start
Operaon of keypad
Example: P420.02
Group 0 – favourites
Group 1 – diagnoscs
Group 2 – basic seng
Control of inverter by means of terminals (default seng)
Time
Frequency
Save parameters:
Flashes = Not saved
On = saved)
EN-gb
(
Setpoint frequency
10 VDC supply
24 VDC, 100 mA supply
Start
GND
* P450.01 setpoint frequency: Preset freq.val. 1
* P450.02 setpoint frequency: Preset freq.val. 2
* P450.03 setpoint frequency: Preset freq.val. 3
Define input range of analog input 1:
[Hz]
[Hz]
* P430.02 minimum frequency
* P430.03 maximum frequency
Navigaon in the menu
Parameter alteraon
Go to Menu/Parameters
Confirm parameter
Quit Menu/Parameters
CTRL
Keypad control
Start motor
R F
Change direcon of rotaon
Stop motor
I/O seng
Fct. dig. outputs
DO1 funcon
Setpoint frequency
10 VDC supply
24 VDC, 100 mA supply
Start
Reset error
Change direcon of rotaon
Acvate preset (bit 0)
Acvate preset (bit 1)
GND