Rated data
Inverter power supply 400 V, self-venlated motors
Motor MCS 06C60- MCS 06C41- MCS 06F60- MCS 06F41- MCS 06I60- MCS 06I41-
Standsll torque M
0
Nm 0.800 0.800 1.50 1.50 2.00 2.00
Rated torque M
rated
Nm 0.500 0.600 0.900 1.20 1.20 1.50
Max. torque M
max
Nm 2.40 2.40 4.40 4.40 6.20 6.20
Rated speed n
rated
rpm 6000 4050 6000 4050 6000 4050
Max. speed n
max
rpm 8000 8000 8000 8000 8000 8000
Rated power P
rated
kW 0.31 0.25 0.57 0.51 0.75 0.64
Standsll current I
0
A 2.50 1.30 2.90 1.50 3.40 1.70
Rated current I
rated
A 2.40 1.30 2.50 1.50 2.90 1.60
Max. current I
max
A 10.8 5.40 10.5 5.30 11.8 5.90
Rated voltage V
rated
V 135 225 180 320 190 325
Rated frequency f
rated
Hz 400 270 400 270 400 270
Moment of inera J kgcm² 0.140 0.140 0.220 0.220 0.300 0.300
Eciency η 0.7 0.65 0.81 0.77 0.84 0.81
Torque constant Kt
0 150
°C
Nm/A 0.320 0.615 0.517 1.00 0.588 1.18
Voltage constant KE
LL 150
°C
V/
(1000/
min)
17.89 35.79 29.33 58.76 35.88 71.77
Stator terminal resistance R
UV 20
°C
Ω 6.8 27 5.4 21.8 4.6 18.8
Stator terminal resistance R
UV 150
°C
Ω 10.248 40.689 8.138 32.853 6.932 28.332
Stator inductance L mH 12.8 51.0 15.9 63.5 15.1 60.2
Weight m kg 2.30 2.30 2.70 2.70 3.40 3.40