Loading...
Environmental condions
Climate
Storage
EN IEC
60721-3-1:1997
1K3 (-20 ... +40 °C) >3 months
1K3 (-20 ... +60 °C) <3 months
Transport
EN IEC
60721-3-2:1997
2K3 (-20 ... +70 °C)
Operaon
EN IEC
60721-3-3:1995 +
A2:1997
3K3 (-10 ... +40 °C) Operaon with brake
3K3 (-15 ...+40 °C) Operaon without brake, forced venlated
3K3 (-20 ...+40 °C) Operaon without brake, self-venlated
Site altude
0 … 1000 m amsl
-
without current derang
1000 … 4000 m amsl Reduce rated output current by 5 %/1000 m
Air humidity
Without
condensaon
- Average relave humidity 85 %
Vibraon resistance
Operaon
EN IEC
60721-3-3:1995 +
A2:1997
3M5
only in operaon with feedback AM20-8V-D or
AM20-8V-D2
3M6
Vibraon severity
A EN 60034-14 - -
Vibraon velocity
Free suspension - 1.6 mm/s
Smooth running, axial runout, concentricity
Normal class
EN 50347 / IEC
60072-1
- -
Technical data
Standards and operang condions
Environmental condions