During operation7
46
BA33.0001 EN 2.0
7Duringoperation
Perform regular inspections during operation. Check the drives approx. every 50 operating
hours. Pay particular a ttention to:
ƒ
Unusual noises
ƒ
Extremely hot surfaces (temperatures of 140°C can occur during normal operation).
ƒ
Oil spots on drive or leakage
ƒ
Irregular running
ƒ
Increased vibration
ƒ
Loose fixing elements
ƒ
Condition of electrical cables
ƒ
Impeded heat dissipation
Deposits on the drive system and in the cooling channels
In case of irregularities or faults: