Mains connecon
Connecon according to EN
The following data is valid for a three-phase mains connecon with 400 V.
Mains connecon with QUICKON connector
Motor MSEMA☐☐063-42 MSEMA☐☐080-32
Connecon X3
Installaon method B2
Connecon type QUICKON connector
Cable type Flexible
cable cross‐secon
Typ.
mm
2
1.5 2.5
Min.
mm
2
1.5 1.5
Max.
mm
2
2.5 2.5
Connecon for single drive according to EN 60204-1
L1
L1
L2
L3
N
PE
F1 … F3
L2
L3
SELV/PELV
DC 24 V
(+19.2 … +28.8 V)
5.6k
5.6k
R
b
M
3~
Rb1 Rb2
V
U
W
+
+
X3
X4
+
1 2 3
BD1BD2
X2
1 2 3
4
X1
1 2 3
4
X5
max. 50 mA
X6
GND
-I
DI1DI2
n. c.
5.6k
GND
-O
DO1
DI3
24V
1
23
4 1
23
4
DC
AC
Q
400
Rb1 Rb2
X4
R
b
Rb1 Rb2
390
Electrical installaon
Mains connecon
Connecon according to EN
61