2 Technical data
EDBZAEBK000X DE/EN/FR/ES/IT 4.0
30
H1_Daten−AllgDaten_c−UL−us_132659_EN
2 Technical data
Field Values
Enclosure IP20 IP65 (EZAEBK200x with EZAMSHHT)
Ambient temperature
In operation: −10 °C ... +55 °C
Transport: −25 °C ... +70 °C
Storage:
−25 °C ... +55 °C
Climatic conditions
Class 3K3 in accordance with EN 50178
(without condensation, average relative humidity 85 %)
Degree of pollution EN 61800−5−1, degree of pollution 2
Conformity and approval
Conformity
EAC
TP TC 020/2011
(TR CU 020/2011)
Electromagnetic
compatibility of
technical means
Eurasian Conformity
TR CU: Technical Regulation
of Customs Union
Approval
C
UL
US
UL 508C Power Conversion Equipment
(File No. E132659) for USA
CSA C22.2
No. 14−13
Power Conversion Equipment
(File No. E132659) for Canada