TRUCKSTER ELECTRIC
SPREADER
SPREADER MOUNTING
The LESCO Truckster Mount Electric Spreader is designed to be mounted to the rear of any turf maintenance
vehicle with a 12-volt electrical system. The vehicle could range from a golf cart to a pickup truck. For this
reason specific mounting instructions cannot be given.
The spreader should be mounted at the center rear of the vehicle so that the impeller is 12 to 18 inches from
the ground. This is important to obtain the proper spreading pattern. The mounting is accomplished by drilling
and bolting through the holes in the mounting plates and the U-frame behind the hopper. The furnished
1/4-20 x 2 inch bolts, lockwashers and nuts should be used. In some cases, depending on the vehicle, your
mechanic may wish to fabricate mounting brackets.
PUSH-PULL SWITCH
This switch should be mounted on the instrument panel or in a position convenient to the driver.
WIRING
With a negative ground system, connect the black (or yellow) motor wire to a good ground point on the
vehicles frame. Run the red (or green) motor wire to the push-pull switch, cut it to length and attach it to one
terminal. Attach the remaining red (or green) wire to the other switch terminal and then to the plus terminal of
the vehicle's 12-volt battery. The motor wiring is provided with a disconnect plug so that the spreader can be
taken off the vehicle and the wiring left intact. Check for proper rotation of the impeller by pulling the push-pull
switch "on" to start the impeller. When viewed from the top of the spreader, the impeller should rotate in a
counterclockwise directions. If the rotation is incorrect, shut-off the switch and reverse the wiring.
CONTROL CABLE
The control cable is used to open and close the spreader. It should be brought to a position within easy reach
of the driver.
OPERATION
PROPER VEHICLE SPEED IS 3 M.P.H.
Adjust the spreader setting rate as recommended by the manufacturer of the product to be applied. At a
speed of 3 m.p.h., the product will be distributed in a spread width of 8 to 12 feet. To spread material, pull the
push-pull switch "on" to start the impeller when the vehicle reaches the area to be treated, then use the
control cable to open the spreader. When you reach the end of the area to be treated, use the control cable
again to close the spreader. Then, with the spreader closed, turn around and then open the spreader again
and make a pass parallel to and 8 feet away from the first. If you keep the passes 8 feet apart, the spreader
patterns will overlap at the sides wheel they thin out and you will achieve even distribution. Reminder to close
the spreader when you stop or turn the vehicle Also push into on the push-pull switch to stop the impeller if
you stop or when traveling from one area to another.
MAINTENANCE
The spreader should be emptied and thoroughly cleaned after each use. Cover the motor and if possible
clean the spreader hopper and working parts with a high pressure water spray.
Do not spray water
directly on the motor.
The motor should be cleaned by blowing it off with an air hose (motor is not
waterproof.) The control cable is attached to the latch arm. Oil the latch-arm pivots after each use.
Model #: 720756
Starting Date: 10/05 -
Question and Answer IconNeed help?

Do you have a question about the Lesco 720756 and is the answer not in the manual?

Lesco 720756 Specifications

General IconGeneral
BrandLesco
Model720756
CategorySpreader
LanguageEnglish

Summary

Spreader Mounting

Push-Pull Switch Installation

Mounting location for the push-pull switch on the instrument panel or driver-convenient position.

Spreader Wiring Instructions

Connect motor wires to ground, push-pull switch, and 12-volt battery; check impeller rotation.

Control Cable Placement

Position the control cable for easy reach to open and close the spreader.

Operation

Optimal Vehicle Speed

Maintain 3 m.p.h. for proper product distribution and an 8-12 foot spread width.

Spreading Material Procedure

Use the control cable to open/close spreader at 3 m.p.h.; overlap passes by 8 feet for even distribution.

Maintenance

Cleaning and Lubrication

Clean hopper with water spray, blow motor with air, oil latch-arm pivots after each use.

Equipment Warranty

Warranty Coverage

Covers conformity to specs and freedom from defects for one year from delivery. Purchaser must notify LESCO.

Exclusions From Warranty

Excludes damage from non-LESCO parts, improper environment, misuse, accidents, unauthorized modifications.

Exclusive Warranty Disclaimer

This warranty is exclusive and in lieu of all other warranties, express or implied, including merchantability.

Limitation of Remedies and Liability

LESCO not liable for indirect, special, or consequential damages arising from equipment use or inability to use.

Warranty Claim Time Limit

All claims must be received by LESCO in writing within 13 months following delivery of the equipment.

Entire Agreement Clause

This written agreement is the complete agreement; no other warranties or liabilities are authorized.

Right to Modify Equipment

LESCO reserves the right to change or modify equipment design without incurring obligations for present equipment.

Allocation Of Risks

This agreement allocates equipment failure risks between LESCO and the purchaser, reflected in the price.

Contacting LESCO Service

Contact LESCO Service Department for warranty support using provided phone numbers and address.

How To Order Parts

Provide account number, shipping details, model/serial number, and LESCO part number for ordering.