DDLS 200
Bus-Capable Optical Data Transmission
en 03-2010/04 50036440
TECHNICAL DESCRIPTION

Table of Contents

Questions and Answers

  • C
    Chris WhiteAug 4, 2025
    Why is bus operation not possible with my Leuze electronic DDLS 200 Microphone system?
    • L
      lsheltonAug 4, 2025
      Bus operation might fail due to several reasons. It could be a transmission error (refer to the troubleshooting section on 'transmission error'), a wiring error (check the wiring), an adjustment error related to termination, baud rate, or configuration (verify settings), an incorrect bus cable (use the specified bus cable), or a deactivated transmitter/receiver unit (ensure correct wiring and S1 position; set to 'Adjust' operating mode, ensuring the ADJ LED is not flashing).
  • M
    Mia JamesAug 16, 2025
    What to do if ADJ LED flashes on Leuze electronic DDLS 200?
    • M
      Melissa BeckerAug 16, 2025
      The ADJ LED might be flashing because of a light beam interruption or no visual connection to the opposing device when it is in 'Manual' operating mode. Check the light path. Another reason could be misalignment of a DDLS 200 when the opposing device is in 'Manual' operating mode; realign the transmission path.
  • Z
    Zachary VargasAug 22, 2025
    Why PWR or UL LED flashes in Leuze electronic DDLS 200?
    • M
      Michele NguyenAug 22, 2025
      The PWR or UL LED flashing indicates that the transmitter/receiver unit is switched off via input IN. Check input IN and the position of switch S1. Alternatively, it could indicate a hardware defect, in which case replace the device and send it in for repair.
  • D
    Douglas OlsenAug 27, 2025
    How to fix PWR or UL LED when it does not illuminate on Leuze electronic DDLS 200 Microphone system?
    • C
      Chelsea ClarkAug 27, 2025
      If the PWR or UL LED does not illuminate, the possible cause is that there is no supply voltage. Check the connections and supply voltage at the device and switch it back on. Another possible cause is a hardware defect. In this case, replace the device and send it in for repair.
  • M
    mcintoshhannahNov 9, 2025
    What to do if my Leuze electronic DDLS 200 Microphone system has a transmission error?
    • J
      Jessica GilbertNov 9, 2025
      If you are experiencing a transmission error, consider the following potential causes and solutions: * Incorrect bus termination: Disconnect/connect terminating resistors. * Shielding not connected: Connect shielding correctly. * Receiving level too low due to misalignment: Realign, checking in 'Adjust' operating mode. * Receiving level too low due to soiling: Clean the optical window. * Receiving level too low due to operation with excessively large operating ranges: Observe operating limits. * Earth lead not connected: Connect the earth lead. * Influenced by parallel data path: Operate data transmission units with alternating frequency assignments, and check parallel distances. * Influenced by cascading data paths: Operate data transmission units with alternating frequen...

Summary

Safety Notices

Safety Standards

Details compliance with safety standards and UL listing.

Intended Use

Specifies optical data transmission in the infrared range.

Working Safely

Covers artificial optical radiation (LED Class 1) and device modifications.

Organizational Measures

Includes documentation, safety regulations, and qualified personnel.

Technical Data

General Technical Data

Lists electrical, optical, mechanical, and environmental specifications.

Mounting and Installation

Mounting and Alignment

Instructions for mounting devices and aligning optical axes.

PROFIBUS; RS 485

PROFIBUS Connection - Terminals

Wiring and switch settings for terminal connections.

PROFIBUS Connection - M12 Connectors

Wiring details for M12 connectors.

Device Configuration PROFIBUS

Setting transmission rates and termination.

INTERBUS 500 kbit;s; RS 422

Electrical Connection

Wiring for INTERBUS 500kbit/s and RS 422.

Device Configuration INTERBUS

Setting switch S4 for bus direction and shielding.

INTERBUS 2 Mbit;s Fiber-Optic Cable

Fiber-Optic Cable Connection

Connecting fiber-optic cables using FSMA connectors.

Data Highway + (DH+); Remote I;O (RIO)

DeviceNet; CANopen

Ethernet

Commissioning and Operation

Initial Commissioning

Steps for powering on, self-test, and initial setup.

Fine Adjustment

Procedure for aligning devices for optimal data transmission.

Diagnostics and Troubleshooting

Troubleshooting

Table of common errors, causes, and remedies.

Leuze electronic DDLS 200 Specifications

General IconGeneral
BrandLeuze electronic
ModelDDLS 200
CategoryMicrophone system
LanguageEnglish