DDLS 200
Bus-capable optical data transmission
EN 2020/01/14 50143516
We reserve the right to make
technical changes
Original operating instructions
DDLS200_E.book Seite 1 Mittwoch, 19. Februar 2020 12:22 12

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Leuze electronic DDLS 200 Series and is the answer not in the manual?

Leuze electronic DDLS 200 Series Specifications

General IconGeneral
BrandLeuze electronic
ModelDDLS 200 Series
CategoryAccessories
LanguageEnglish

Summary

General Information

Explanation of Symbols

Explains warning symbols and notes used in the technical description.

Declaration of Conformity

States compliance with European standards and ISO 9001 quality assurance.

Short Description

Introduces the DDLS 200 series as high-performance optical data transmission systems.

Operating Principle

Explains the use of two frequency pairs for duplex operation to prevent interference.

Safety Notices

Safety Standards and Intended Use

Covers safety standards compliance, intended use, and application areas for the DDLS 200.

Working Safely and Organizing Measures

Details safety regulations, qualified personnel requirements, and documentation.

Technical Data

General Technical Data

Lists electrical, optical, and mechanical specifications, including operating range and protection.

Dimensioned Drawings

Provides physical dimensions, connection details, and cable specifications for the DDLS 200.

Mounting and Installation

Mounting and Alignment

Guides on how to mount devices, ensure alignment, and avoid transmission interruptions.

Arrangement of Adjacent Transmission Systems

Provides measures to prevent mutual interference between adjacent transmission systems.

Cascading (Series Connection) of DDLS 200 Data Paths

Explains how to connect multiple DDLS 200 systems in series for extended data paths.

Electrical Connection

Details electrical connections for supply voltage, inputs, outputs, and bus systems.

PROFIBUS / RS 485

Connection - Devices with Screwed Cable Glands and Terminals

Describes PROFIBUS electrical connections using screwed cable glands and terminals.

Connection - Devices with M12 Connectors

Details PROFIBUS electrical connections using M12 connectors.

Device Configuration PROFIBUS

Covers settings for termination, baud rate, and mode switching for PROFIBUS.

LED Indicators PROFIBUS

Explains the meaning of status LEDs for PROFIBUS models.

INTERBUS 500kBit/s / RS 422

Electrical Connection INTERBUS 500kBit/s

Details the electrical connection for INTERBUS 500kBit/s using terminals.

Device Configuration INTERBUS 500kBit/s / RS 422

Covers configuration of incoming/outgoing bus and shielding connection for INTERBUS.

LED Indicators INTERBUS 500kBit/s / RS 422

Explains the status LEDs for INTERBUS 500kBit/s / RS 422 models.

INTERBUS 2MBit/s FOC

FOC Connection INTERBUS 2MBit/s

Describes the fiber-optic (FOC) connection for INTERBUS 2MBit/s using FSMA connectors.

Device Configuration INTERBUS 2MBit/s FOC

Covers transmission rate and incoming/outgoing bus configuration for INTERBUS FOC.

LED Indicators INTERBUS 2MBit/s FOC

Explains the status LEDs for INTERBUS 2MBit/s FOC models.

Data Highway + (DH+) / Remote I/O (RIO)

Electrical Connection DH+ / RIO

Details the electrical connection for Data Highway + and Remote I/O buses.

Device Configuration DH+ / RIO

Covers cascading, filter settings, and transmission rate adjustments for DH+/RIO.

LED Indicators DH+ / RIO

Explains the status LEDs for Data Highway + / Remote I/O models.

DeviceNet / CANopen

Electrical Connection

Details wired connections for DeviceNet/CANopen, including transceiver power options.

M12 Connector Electrical Connection

Describes electrical connections for DeviceNet/CANopen using M12 connectors.

Device Configuration

Covers baud rate conversion, sorting, and bus length settings for DeviceNet/CANopen.

Wiring and Termination

Explains DeviceNet/CANopen wiring principles and bus termination requirements.

LED Indicators

Explains the status LEDs for DeviceNet/CANopen models.

Transmission Path Interruption

Describes system response to interruptions and participant monitoring mechanisms.

System Integrator Information

Provides notes on segmentation, time behavior, synchronous messages, and implementation.

Ethernet

Connection - Devices with Screwed Cable Glands and Terminals

Details Ethernet connection using RJ45 socket, including switch settings for autonegotiation.

Connection - Devices with M12 Connectors

Describes Ethernet electrical connections using M12 connectors.

Device Configuration

Covers autonegotiation, transmission rate conversion, and network expansion for Ethernet.

Wiring

Explains Ethernet wiring, distinction between 1:1 and crossover cables, and RJ45/M12 assignments.

LED Indicators Ethernet

Explains the status LEDs for Ethernet models.

System Integrator Information

Provides notes on bus configuration, receive buffers, and primary transmission protocols.

Commissioning / Operation

Indicators and Operational Controls

Describes the bar graph, operating mode LEDs (AUT, MAN, ADJ), and operating mode button.

Operating Modes

Provides an overview of operating modes: Automatic, Manual, and Adjust.

Initial Commissioning

Details the self-test, LED status checks, and the procedure for fine alignment.

Operation

Covers maintenance-free operation, cleaning requirements, and response to beam interruption.

Maintenance

Cleaning

Provides instructions for cleaning the optical window using a soft cloth and glass cleaner.

Diagnostics and Troubleshooting

Status Indicator on the Device

Explains how device LEDs indicate faults and errors across different models.

Diagnostic Mode

Details how to enter and use diagnostic mode for monitoring received signal levels.

Troubleshooting

Lists common faults, possible causes, and remedies for device operation issues.

Accessories

Terminating Resistors

Lists M12 terminating resistors for PROFIBUS and DeviceNet/CANopen BUS OUT.

Connectors

Lists M12 connector sockets and pins for PROFIBUS and voltage supply.

Ready-Made Cables for Voltage Supply

Provides contact assignment, technical data, and order codes for PWR connection cables.

Ready-Made Cables for Interface Connection

Lists cables for PROFIBUS and Industrial Ethernet, including technical data and order codes.