EasyManua.ls Logo

Leuze electronic DDLS 200 Series - Device Configuration DH+; RIO

Leuze electronic DDLS 200 Series
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data Highway + (DH+) / Remote I/O (RIO)
Leuze electronic DDLS 200 33
TNT 35/7-24V
8.2 Device configuration DH+ / RIO
Cascading of multiple DDLS 200 transmission paths (filter, default: ’On’ = on)
If multiple DDLS 200 transmission paths are to be cascaded within a bus segment (see figure 8.2),
the filter for interference-peak suppression (switch S3-1) must be adjusted appropriately for the se-
lected transmission rate. Observe also the notices in Chapter 4.3.
Figure 8.2: Cascading multiple optical transmission paths with DH+ / RIO
In accordance with the following table, set the filter for each DDLS 200 transmission path at both de-
vices for the given path using switch S3-1.
Table 8.1: Filter settings when cascading multiple DDLS 200 transmission paths
Baud rate
Position of S3-1 for
1 path 2 paths 3 paths
57.6kBit/s Path 1: On (1)
Path 1: On (1)
Path 2: Off (0)
Path 1: On (1)
Path 2: Off (0)
Path 3: Off (0)
115.2kBit/s
and
230.4kBit/s
Path 1: On (1)
Path 1: On (1)
Path 2: On (1)
Path 1: On (1)
Path 2: On (1)
Path 3: On (1)
Path 1
Path 1
Path 1
Path 2
Path 2 Path 3
1 DDLS 200 transmission path
2 DDLS 200 transmission paths
3 DDLS 200 transmission paths
PLC
PLC
PLC
DDLS200_E.book Seite 33 Mittwoch, 19. Februar 2020 12:22 12