Technical data
8 DDLS 200 Leuze electronic
3 Technical data
3.1 General technical data
Electrical data
Supply voltage Vin 18 30VDC
Current consumption without optics
heating
Approx. 200 mA at 24 V DC (no load at switching output)
Current consumption with optics
heating
Approx. 800 mA at 24 V DC (no load at switching output)
Optical data
Operating range 0.2 30m (DDLS 200/30…)
0.2 80m (DDLS 200/80…)
0.2 120m (DDLS 200/120…)
0.2 200m (DDLS 200/200…)
0.2 300m (DDLS 200/300…)
0.2 500m (DDLS 200/500…)
Transmission diode Infrared light, wavelength 880 nm
Opening angle ± 0.5° with respect to the optical axis for 120m 500 m mod-
els,
± 1.0° with respect to the optical axis for 80 m models,
± 1.5° with respect to the optical axis for 30 m models
Ambient light > 10000 Lux acc. to EN 60947-5-2:2008
LED risk group Exempt group in acc. with EN 62471
Input/output
Input 0 2VDC: transmitter/receiver deactivated
18 30VDC: transmitter/receiver activated
Output 0 2VDC: normal operation
Vin 2VDC: limited function reserve
Output current max. 100 mA, short-circuit proof, protected
against overvoltage, transients and overheating
Controls and indicators
Membrane keyboard Change of operating mode
Individual LEDs Display of voltage supply, operating mode, data communica-
tion (dependent on type)
LED strip Bar graph indicator of the received signal level
Mechanical data
Housing Diecast aluminum; optical inlet/outlet, glass
Weight Approx. 1200 g
Degree of protection IP 65 acc. to EN 60529:2000
DDLS200_E.book Seite 8 Mittwoch, 19. Februar 2020 12:22 12