Device description
Leuze electronic MSI-MD-FBX 11
3.1 Device construction
2
4
5
7
8
6
3
1
1 Mounting eyes for M4 screws
2 Cover for the DIP switch blocks for configuring the muting function and the Micro USB connection for reading
out diagnostics.
3 7‑segment display
4 Connection for the safety sensor
5 Connection for acknowledgment unit
6 Connections for muting sensors
7 Connection for external muting indicator
8 Connection to the machine interface (OSSDs and supply voltage)
Fig.3.1: Device construction of the muting controller

Table of Contents