Technical data
Leuze electronic MSI-MD-FBX 41
13 Technical data
13.1 General specifications
Tab.13.1: Safety-relevant technical data
Performance Level (PL) PLe, Cat.4 in accordance with ENISO13849
Safety Integrity Level (SIL) SIL3 in accordance with IEC61508
SIL Claim Limit (SILCL) SILCL3 in accordance with IEC/EN62061
Probability of a dangerous failure per hour (PFH
d
) 2.5+10E-9
Mission time (T
M
) 20 years
Tab.13.2: General system data
Connection technology M12 connectors, 5-pin, female
M12 connectors, 8-pin, male
Supply voltage U
v
+24V, ± 20%, compensation necessary at 20ms
voltage dip, min.250mA (+external load)
Residual ripple of the supply voltage ± 5% within the limits of U
v
Current consumption 150mA (without load)
Protection class III
Degree of protection IP 67 acc. to EN60529
Reaction time ≤ 5 ms
Ambient temperature, operation -30…+60°C
Ambient temperature, storage -40…+70°C
Relative humidity (non-condensing) 0…95%
Vibration resistance 10-55 Hz in acc. with IEC/EN60068-2-6; 0.35mm
amplitude
Shock resistance 100m/s
2
acceleration, 16ms acc. to IEC/
EN60068-2-6
Dimensions (LxWxH) 225mmx60mmx37mm
Weight 560g
Maximum length of the connection cable to the ma-
chine interface
50 m
Only permissible with a maximum additional current
demand ≤160mA
Torque for the screws of the cover 0.6…0.8Nm