Figure 7: Basic dimensions of interface panel FIP-2.1
Figure 8: Basic dimensions of user panel LUI-B.1
2.4 General Environmental Conditions
Operating ambient temperature
Storage ambient temperature
(Extremes for Transportation)
Operating humidity range (relative humidity)
15 – 95% (non-condensing)
Storage humidity range (relative humidity)
(Extremes for Transportation)
15 – 95% (non-condensing)
Normal storage conditions
Ambient temp.: 20 to 30°C
Relative humidity: 50% (non-condensing)
Transient over-voltages typically present on
the mains supply
Surge immunity according to EN 61000-4-5
(tested together with certified AC/DC power supply)
Table 3: Environmental conditions for bearingless fan