480L Quick Reference Guide
Lexicon Part # 070-09361 Rev 1
3 Oak Park • Bedford MA 01730-1441  USA • Telephone: 617-280-0300 • Fax: 617-280-0490
5. Loading a Register
If you set up the 480L with a
Split or Cascade configura-
tion, you can load a second
program or register into ma-
chine B.
The 480L stores five banks
(1-5)  of  ten  user-program-
mable  registers  in  internal
memory. Another five banks
(6-10) of ten registers can be
stored  in  a  cartridge
plugged into the front panel
of the 480L.
4. Storing Edited Programs in Registers
The LARC
After loading a program, you
can edit its parameters with
the LARC's sliders.
A code appears in  the dis-
play  window  above  each
slider. To display the com-
plete title in the main display,
move the slider, or press the
key directly below the slider.
3. Editing Parameters
2. Loading a Program
Example:  To load program 5.6, Rebound, press BANK  5  to
select the Effects bank. Then press PGM 6 to load the program.
Press  MACH  to  switch
LARC control to machine B.
Now use BANK , PGM , and
the numeric keys to load a
program. Switch control be-
tween machine A and B at
any time by pressing MACH.
1. Choosing a Configuration
Cascade Configuration
Mono Split Configuration
Machine
A
Inputs
L
L R
Main Outputs
Machine
B
L R
Aux Outputs
R
Press REG repeatedly to find
the register you want to load.
Press the number of the reg-
ister  you  want  to  load  into
machine A.
If you set up the 480L with a
Split or Cascade configura-
tion, you can load a second
program into machine B.
In  the  Single  configuration,
the 480L runs one program.
In the Cascade, Stereo Split,
and  Mono  Split  configura-
tions, it can run two programs
simultaneously.
To choose a  configuration,
press CTRL to enter the con-
trol mode.
Use slider 2 on page 1 to
choose one of the four con-
figurations shown below.
Press CTRL again to exit the
control mode.
Single Configuration
Stereo Split Configuration
Machine
A
LR
Aux Outputs
Machine
B
Inputs
L R
L R
Main Outputs
Machine
A
Inputs
L
L R
Main Outputs
Machine
B
R
L R
Aux Outputs
Machine
A
Inputs
L R
L R
Main Outputs
Use BANK to select the bank
that  contains  the  program
you  want.  Press  BANK  re-
peatedly to scroll through all
the banks, or  press BANK
and a numeric key to go di-
rectly to the bank you want.
Press PGM and the number
of the program you want to
load into machine A.
To store an edited version of
a  program  in  a  register,
press REG once to enter the
register mode. Press BANK
repeatedly to locate the bank
you want to store the register
in.
Most programs have several
pages of parameters. Press
PAGE  to  step  through  the
pages. Press  PAGE and  a
numeric key to go directly to
the page you want.
Press  REG  repeatedly  to
locate an "Unused" register,
or  any  register  you  don't
mind  erasing.  Hold  down
STO and press REG at the
same time. The register is
now stored.
Press  REG  to  switch  from
program to register mode.
Use BANK to select the bank
that  contains  the  register
you  want.  Press  BANK  re-
peatedly to scroll through all
the banks, or  press BANK
and one of the numeric keys.
This completes the basic introduction to the Lexicon 480L. For
detailed explanations of the many features and capabilities
not described here, read the 480L Owner's Manual.