Lexicon
MC-12 Serial Communications Protocol Printed on: 07/19/04
© 2004 Harman Specialty Group All rights reserved. 43 of 102
ParamId:
Data Type: Unsigned 16 bit integer.
Max: Max Parameter Count as reported by the MC-12 Unit Configuration
Response Packet in 7.3.39.2
7.3.41.3 Data Validation
If ParamId exceeds the its maximum value, the MC-12 will ignore the command and transmit a
DC_NAK command with an error code DC_INVALID_PARAM_ID.
7.3.41.4 MC-12 Value String Response Packet
Application Header:
Command MC_RESP_PARAM_VALUE 0x92
Data Count 24 0x18
Application Data:
Data[0] ParamId (LSB) nn
Data[1] ParamId (MSB) nn
Data[2] ParamType nn
Data[3-23] Value[0 -20]
nn nn
nn…
7.3.41.5 Data Description
Same as Paragraph 7.3.37.2
7.3.42 MC-12 Set Parameter Notification by Id (MC-12)
Request to MC-12 to enable or disable transmission of the MC-12 parameter change notification for a given
parameter.
7.3.42.1 Command Packet Description
Application Header:
Command MC_CMD_SET_PARAM_NOTIFICATION_BY_ID 0x3B
Data Count 3 0x03
Application Data:
Data[0] ParamId (LSB) nn
Data[1] ParamId (MSB) nn
Data[2] Enable/Disable nn
7.3.42.2 Data Description
ParamId:
Data Type: Unsigned 16 bit integer.
Max: Max Parameter Count as reported by the MC-12 Unit Configuration
Response Packet in 7.3.39.2
Enable/Disable:
Data Type: Boolean
TRUE: Enable transmission of parameter notification
FALSE: Disable transmission of parameter notification
7.3.42.3 Data Validation

Table of Contents