EasyManua.ls Logo

Lexmark X63 - Scanner Motor with Gear Assembly Service Check

Lexmark X63
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-10 Service Manual
4400-001
Scanner Motor with Gear Assembly Service Check
Motor will not run.
FRU Action
1 Scanner Motor with Gear
Assembly
Check scanner motor for shorts.
Disconnect connector CN8 from the
system board and check for
approximately 12.5 ohms between
the following pins on the motor
connector.
CN8-1 and CN8-2
If the ohms reading is incorrect,
replace the scanner motor assembly.
If the motor does not come on during
the scanning process, check
connector CN8 on the system board.
If the connection is okay, check for
voltage reading of approximately 28
volts at pins
CN8-1
CN8-2
CN8-3
CN8-4
If voltage is correct, replace the
scanner motor with gear assembly.
Go to the Scanner Motor with
Gear Assembly Removal on
page 4-9. If voltage is incorrect,
replace the system board. Go to the
System Board Removal on
page 4-21.
2 Document Scanner Sensor To check the document scanner
sensor, insert a sheet of paper or
depress the sensor to see if the
scanner motor is working. Go to
Operator Panel Problems on
page 2-3.